1 689 979 924N 26.11.07 85
15.4 Error pedal force measuring gauge
Error code 11 20 *
No signal pedal force measuring gauge (cable version)
Cause:
- Pedal force measuring gauge cable version has been activa-
ted in the configuration menu, but does not exist physically.
- Connecting line defective
- Sensor defective
Error code 11 22 *
Pedal force measuring gauge (cable version) not yet calibrated.
Error code 11 25 *
When switching on, zero point pedal force measuring gauge
(cable version) from EEPROM compares to current pedal force.
In case of a difference > 20 N, the error is displayed.
Cause:
- Pedal force measuring gauge cable version has been activa-
ted in the configuration menu, but does not exist physically.
- Pedal force measuring gauge not yet calibrated.
- Pedal force measuring gauge is loaded when switching on.
15.5 Error radio sensors
Error code 14 10 *
No connection to radio base station PCB A8
Cause:
- Radio module has been activated in the configuration menu,
but does not exist physically.
- Incorrect DIP switch setting on PCB A2 S1
- PCB A8 defective
Error code 14 20 *
No signal pressure sensor Pm (radio version) during the measu-
rement.
Cause:
- Pressure sensor Pm (radio version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor defective
- Accumulator empty
Error code 14 30 *
No signal pressure sensor Pz (radio version) during the measure-
ment.
Cause:
- Pressure sensor Pz (radio version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor defective
- Accumulator empty
Error code 14 40 *
No signal from pedal force measuring gauge (radio version)
during the measurement.
Cause:
- Pedal force measuring gauge (radio version) has been acti-
vated in the configuration menu, but does not exist physically.
- Pedal force measuring gauge defective
- Accumulator empty
15.6 Error pressure sensors cable version
Error code 15 01 *
When switching on, zero point pressure sensor Pm (cable versi-
on) from EEPROM compares to current pressure. In case of a
difference > 0.15 bar, the error is displayed.
Cause:
- Pressure sensor Pm (cable version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor Pm (cable version) not yet calibrated.
- Pressure sensor Pm (cable version) is loaded when swit-
ching on.
Error code 15 02 *
No signal pressure sensor Pm (cable version)
Cause:
- Pressure sensor Pm (cable version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor defective
- Sensor line defective.
Error code 15 03 *
Pressure sensor Pm (cable version) not yet calibrated.
Error code 15 06 *
When switching on, zero point pressure sensor Pz (cable version)
from EEPROM compares to current pressure. In case of a
difference > 0.15 bar, the error is displayed.
Cause:
- Pressure sensor Pz (cable version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor Pz (cable version) not yet calibrated.
- Pressure sensor Pz (cable version) is loaded when switching
on.
Error code 15 07 *
No signal pressure sensor Pz (cable version)
Cause:
- Pressure sensor Pz (cable version) has been activated in the
configuration menu, but does not exist physically.
- Pressure sensor defective
- Sensor line defective.
Error code 15 08 *
Pressure sensor Pz (cable version) not yet calibrated.
15.7 Error wheel tester
Error code 17 00 *
No signal from wheel tester poti.
Cause:
- Wheel tester set has been activated in the configuration
menu, but does not exist physically.
- Sensor line defective.
- Poti defective
Error code 17 02 *
Wheel tester not yet calibrated.