E-100-LR-A  E-100-LR-E
Light Replacement and Retrofit Kit for
High-Profile End Seal Installation Instructions
DESCRIPTION
The nVent RAYCHEM E-100-LR-A and E-100-LR-E light kit is used
to replace the light on an E-100-L high-profile lighted end seal or
to retrofit a light to an existing E-100 high-profile end seal.
This kit may be installed at temperatures as low as –40°F
(–40°C). For easier installation store above freezing until just
before installation.
– E-100-LR-E kit is used for E-100-E and E-100-L-E kits
– E-100-LR-A kit is used for E-100-A and E-100-L-A kits
For technical support call nVent at (800)545-6258.
TOOLS REQUIRED
Wire cutters Rags or dry towel
Utility knife Wire strippers
Marker Needle nose pliers
Panduit CT-100 crimp tool or equivalent
KIT CONTENTS
Item Qty Description
A 1 Light assembly
B 1 Core sealer (for BTV, QTVR, XTV, and KTV)
C 2 Insulated butt splices (red)
D 2 Insulated parallel crimps (blue)
E 1 Cable tie
A
C
B
E
D
APPROVALS
CLI, ZN1, AEx e mb IIC T* Gb
(1)
ZN21 AEx tb IIIC T*
Ex e mb IIC T* Gb
Ex tb IIIC T***°C Db
IECEx SIR 14.0007X
Ex e mb IIC T* Gb IP66
Ex tb IIIC T***°C Db
Hazardous Locations
(1)
Except VPL
* For system Temperature Code, see heating cable or design documentation
.
Class I, Div. 2, Groups A, B, C, D
Class II, Div. 1 and 2, Groups E, F, G
Class III
–WS
sira