[server1]# ./mlxup
Querying Mellanox devices firmware
...
Type: ConnectX-4 Lx
Number: MCX4131A-GCAT
ConnectX®-4 Lx
EN
network
interface card,
50GbE
single-port
QSFP28, PCIe3.0
x8,
tall
bracket
MT_2190110032
PCI Device Name: 0000:06:00.0
Base
GUID: e41d2d0300fd8b8a
Current Available
FW
16.23.1020 16.24.1000
Update required
Type: ConnectX-4 Lx
Number:
MCX4131A-GCAT
ConnectX®-4 Lx
EN
network
interface card,
50GbE
single-port
QSFP28, PCIe3.0
x8,
tall
bracket
MT_2170110021
PCI Device Name: 0000:07:00.0
Perform
FW
update? [y/N]: y
Device #1:
Up
to date
FW
...
Done
Restart needed for updates to take effect.
Log File: /var/log/mlxup/mlxup-yyyymmdd.log
Updating Adapter Firmware
Each adapter card is shipped with the latest version of qualified firmware at the time of manufacturing.
However, Mellanox issues firmware updates occasionally that provide new features and bug fixes. To
check that your card is programmed with the latest available firmware version, download the mlxup
firmware update and query utility. The utility can query for available Mellanox adapters and indicate
which adapters require a firmware update. If the user confirms, mlxup upgrades the firmware using
embedded images. The latest mlxup executable and documentation are available from http://
www.mellanox.com > Products > Software > Firmware Tools.
Firmware Update Example