Ensure use of personal protective equipment. Please read and comply with all safety and
handling instructions as recommended by sanitizer manufacturer.
Required materials:
• Sanitizer/Disinfectant based on 5% Peracetic Acid
• Mild dishwashing soap
• Small bristle brush
• Large bottle/bristle brush
• Philips head screw driver
• ¼ Inch hexagonal head, screw driver
• Sellotape
• Empty sanitizing filter unit.
• Replacement filter media
• Replacement blue tubing [4000mm], knife to cut lengths.
• Cable ties [x 4]
• Container for emptying contaminated cooler, capacity of at least 2 liters.
• Small sink or bucket to hold at least 3 liters of water.
1. Disconnect cooler from Mains Water & Electrical supply.
• Remove and replace inlet tubing with similar length.
2. Expose filter system - removing front door panel from unit.
• Lift out and remove the drip tray. (Diagram 3.1)
• Depress the clip visible through the slot in the alcove and swivel the door forward. (Diagram
3.2)
Diagram 3.1