Oki Data CONFIDENTIAL
43641601TH Rev.1
21 /
2.3.4 Cover Assy Top
(1) Remove the paper feeder. (See 2.3.1.)
(2) Remove the cover assy upper. (See 2.3.2.)
(3) Remove the LED head. (See 2.3.3.)
(4) Remove the screw
and then remove the flat cable from the connector (HEAD).
(5) Push the right clamp outward, disengage the engaging part and then also remove the left engaging
part to remove the cover assy top