Oki Data CONFIDENTIAL
43641601TH Rev.1
23 /
2.3.6 Frame base unit
(1) Remove the paper feeder. (See 2.3.1.)
(2) Remove the cover assy upper. (See 2.3.2.)
(3) Remove the cover assy top. (See 2.3.4.)
(4) Remove the high voltage power supply 1/ sensor board. (See 2.3.5.)
(5) Remove three screws
.
(6) Remove the screw
and then remove the cable and the contact CB .
(7) Remove the inlet
of the low voltage power supply board from the frame base . When removing
the inlet from the frame base , unlock the latch of the inlet from the frame base , using
a flathead screwdriver from the side face of the frame base.
(8) Remove six cables
and disengage two engaging parts, and then remove the frame base .
(9) Remove the screw
and then remove the LED panel board .