Oki Data CONFIDENTIAL
43641601TH Rev.1
33 /
2.3.12 Fuser Assy
(1) Remove the paper feeder. (See 2.3.1.)
(2) Remove the cover assy upper. (See 2.3.2.)
(3) Remove the cover assy top. (See 2.3.4.)
(4) Remove the high voltage power supply 1/ sensor board. (See 2.3.5.)
(5) Remove two screws
and connector and then remove the heat assy .
(The back up roller also comes off at this time.)