Replacing consumables and maintenance unit
- 70 -
IndexTroubleshooting
1
2
Maintenance
4
Push the center lever (blue) to the
right.
5
Rotate the belt unit left/right lock lever
knob (blue) to the left, and push the
lock lever towards yourself.
6
Hold the handle and pull out the belt
unit, hold the left-right label part (blue)
and remove the belt unit.
6.6 kg
Note
z
Do not touch the belt surface or damage the belt.
z
Removing the belt unit will expose all image drums
to light. For preventing the optical deterioration of
image drums, do not leave them as it is for more
than 5 minutes after removing the belt unit.
When leaving for more than 5 minutes, close the
front cover, or remove all image drums and store
them in a safe place where they are not directly
exposed to sunlight or uorescent light.