EasyManua.ls Logo

Oki MSM85C154HVS - External Program Memory Access AC Characteristics

Oki MSM85C154HVS
378 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ELECTRICAL CHARACTERISTICS
221
6.4 External Program Memory Access AC Characteristics
V
CC
=2.2 to 6.0V, V
SS
=0V, Ta=–40°C to +85°C
PORT 0, ALE, and PSEN connected with 100pF load, other connected with 80pF load
Parameter Symble Unit
Min. Max.
1 to 24 MHz
Variable clock from
41.7 1000 ns
t
CLCL
XTAL1, XTAL 2 Oscillation Cycle
2t
CLCL
-40 ns
t
LHLL
ALE Signal Width
1t
CLCL
-15 ns
t
AVLL
Address Setup Time
(to ALE Falling Edge)
1t
CLCL
-35 ns
t
LLAX
Address Hold Time
(from ALE Falling Edge)
—4t
CLCL
-100 ns
t
LLPL
Instruction Data Read Time
(from ALE Falling Edge)
1t
CLCL
-30 ns
t
LLPL
From ALE Falling Edge to PSEN
Falling Edge
3t
CLCL
-35 ns
t
PLPH
PSEN Signal Width
—3t
CLCL
-45 ns
t
PLIV
Instruction Data Read Time
(from PSEN Falling Edge)
0—ns
t
PXIX
Instruction Data Hold Time
(from PSEN Rising Edge)
—1t
CLCL
-20 ns
t
PXIZ
Bus Floating Time after Instruction
Data Read (from PSEN Rising Edge)
—5t
CLCL
-105 ns
t
AVIV
Instruction Data Read Time
(from Address Output)
0—ns
t
AZPL
Bus Floating Time(PSEN Rising
Edge from Address float)
1t
CLCL
-20 ns
t
PXAV
Address Output Time from PSEN
Rising Edge
*1
*1 The variable check is from 0 to 24 MHz when the external check is used.

Table of Contents