EasyManua.ls Logo

Oki MSM85C154HVS - 32-Bit Timer Mode

Oki MSM85C154HVS
378 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
INTERNAL SPECIFICATIONS
89
4.5.2.5.6 32-bit timer mode
When “1” is set in bit 6 (T32) of the I/O control register (IOCON 0F8H), timer/counters 0 and
1 are connected serially as indicated in Figure 4-18 to become a 32-bit timer/counter.
This 32-bit timer/counter is started by the following procedure. First, “0” is set in TR0, TR1,
TF0, and TF1 of the timer control register (TCON 88H) to stop the timer/counter and reset the
timer flag.
Next timer/counter preset data values are set in timer/counters 0 and 1, and a counter clock
designation is set in bit 2 (C/T) of the timer mode register (TMOD 89H).
If “1” is then set in bit 6 (T32) of the 1/0 control register (IOCON 0F8H) after completing the
above procedure, the 32-bit timer/counter is established and counting is commenced. This
32-bit timer/counter is especially useful in cancelling CPU power down mode. (See power
down mode cancellation.)
Figure 4-18 32-bit timer/counter
Q0-----Q7
TL0
(8BITS)
XTAL 1 ÷
12
DETECTOR
T0 PIN
(PORT 3.4)
C/
T
(TMOD bit2)
Q0-----Q7
TH0
(8BITS)
Q0-----Q7
TL1
(8BITS)
Q0-----Q7
TH1
(8BITS)
TF1
76543210
T32
SERR
IZC
P3HZ P2HZ P1HZ
ALF
IOCON [0F8H]