2.3 - MOBILE INSTALLATION
The air conditioner must be installed in a suitable environment.
It is recommended to reduce solar radiation through curtains, Venetian blinds and to keep doors and windows
closed.
a. Position the air conditioner in front of a window or French window.
b. Inserttheexiblehose(1)terminalontheairoutletgridoftheappliance(26)asshowningure8.
c. Foldtheconveyor(2)endbackonitselfandinsertitintotheexiblehose(1)(g.9).
d. Position the terminal (2) in such a way as to make air exit to the exterior (Fig.9a)
e. Ifyoupossessa sliding window(verticalorhorizontal)or a shutter,itispossibletouse the supplied
SLIDER(8)whichallowsamoreefcientinstallation.
FortheinstallationwithSLIDER(8),proceedasshowningures8and8a.
f. Position the SLIDER (8) and adapt it (Fig.8a)
g. Positiontheexiblehose(1)(Fig.8a)
Extend the pipe only to the necessary extent, so that the air conveyor remains closed between
the xture shutters (Fig.10).
2.4 - ELECTRICAL CONNECTION
Theapplianceisttedwithapowercablewithplug.
Before connecting the air conditioner ensure that:
• Thevoltageandpowerfrequencyvaluesmatchthosespeciedonthe
appliance plate data.
• Thepowerlineisequippedwithaneffectiveearthconnectionandis
correctlysizedformaximumpowerconsumptionoftheairconditioner.
• The appliance’s power network must be equipped with a suitable
omnipolar disconnection device compliant with national installation
regulations.
• Theapplianceispoweredsolelythroughasocketcompatiblewiththeplugprovided.
CAUTION
AnyreplacementofthepowercablemustbecarriedoutsolelybyOlimpiaSplen-
didtechnicalsupportorbysimilarlyqualiedpersonnel.