EasyManua.ls Logo

Olympus bx40 - Page 36

Olympus bx40
50 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1-UB525
1-UB527
1-UB535
1-UB536
1-UM527
1-UM230
1-UM530
1-UM935
1-UC123
TUC125
1-UC127
1-UC135
UPLFL20X:
20X
U
Plan
Fluorite
“Universal”
Objective,
infinity-corrected,
EN.
26.5;
N.A.
0.50;
W.D.
1.60mm;
spring-
loaded,
For
brightfield,
darkfield,
Nomarski
DIC,
polarization
and
high
UV
transmission
fluorescence.
UPLFL40X:
40X
U
Plan
Fluorite
Dry
“Universal”
Objective,
infinity-corrected,
FIN.
26.5;
N.A.
0.75;
W.D.
0.51mmm;
spring-loaded.
For brightfield,
darkfield,
Nomarski
DIC,
polarization
and
high
UV
transmission
fluorescence.
UPLFL100X0:
100X
U
Plan
Fluorite
Oil
Immersion
“Universal”
Objective,
infinity-corrected,
F.N.
26.5;
N.A.
1.30;
W.D.
0.10mm;
spring-loaded.
For
brightfield,
Nomarski
DIC,
polarization
and
high
UV
transmission
fluorescence.
UPLFL100XOI:
100X
U
Plan
Fluorite
Oil
Immersion
“Universal”
Objective
with
Iris,
infinity-corrected,
F.N.
26.5;
N.A.
variable
from
1.30
to
0.70.
W.D.
0.10mm;
spring-loaded.
For
brightfield,
darkfield,
Nomarski
DIC,
polarization
and
high
UV
transmission
fluorescence.
NO
COVER GLASS
OBJECTIVES
UMPLFL40X:
Universal
Plan
Fluorite
40X
Reflected
Light
Objective,
infinity-corrected,
RMS
thread.
ΕΝ.
26.5:
N.A.
0.75;
W.D.
0.63,
spring-loaded.
Biological
applications:
examination
of
smears
and
other
non-coverslipped
specimens
which
require
a
“No
Cover
Glass”
objective
for
brightfield,
darkfield,
Nomarski
DIC,
polarization
and
fluorescence
techniques.
MPLS0X:
M
Plan
Achromat
50X Reflected
Light
Objectives,
infinity-corrected,
RMS
thread. F.N.22;
N.A.
0.75;
W.D.
0.38mm;
spring-loaded.
Biological
applications:
examination
of
smears
and
other
non-coverslipped
specimens
which
require
a
“No
Cover
Glass’
objective
for
brightfield,
darkfield
and
visible
wavelength
fluorescence
techniques.
UMPLFL50X:
Universal
Plan
Fluorite
50X Reflected
Light
Objective,
infinity-corrected,
RMS
thread.
F.N.
26.5;
Ν.Α.
0.80;
W.D.
0.70mm;
spring-loaded.
Biological
applications:
examination
of
smears
and
other
non-coverslipped
specimens
which
require
a
"No
Cover
Glass”
objective
for
brightfield,
darktield,
Nomarski
DIC,
polarization
and
fluorescence
techniques.
MPLAPO100X0:
M
Plan
Apochromat
100X
Oil
Reflected
Light
Objective,
infinity
corrected,
RMS
thread.
F.N.
26.5;
М.А.
1:40;
W.D.
0.10mm;
spring-loaded.
Biological
applications:
examinations
of
smears
and
other
non-
coverslipped
specimens
which
require
a
"No
Cover
Glass’
objective
for
brightfield,
Nomarski
DIC,
polarization
and
fluorescence
techniques.
PHASE
CONTRAST
OBJECTIVES
-
ACHROMAT
(for
eyepieces
with
F.N.
up
to
22)
ACH10XPH:
10X
Achromat
Flatfieid
Phase
Contrast
Objective,
infinity-corrected,
EN.
22;
М.А.
0.25;
W.D.
610mm.
For
use
with
PH1
Phase
Annulus.
ACH20XPH:
20X
Achromat
Flatifeld
Phase
Contrast
Objective,
infinity-corrected,
FN.
22;
N.A.
0.40;
W.D.
300mm.
For
use
with
PH1
Phase
Annulus.
ACH40XPH:
40X
Achromat
Flatfield
Phase
Contrast
Objective,
infinity-corrected,
F.N.
22;
N.A.
0.65;
W.D,
0.45mmi
spring-loaded.
For
use
with
PH2
Phase
Annulus.
ACH100XOPH:
100X
Achromat
Fiatfield
Phase
Contrast
Oil
Immersion
Objective;
infinity-corrected,
EN.
22;
N.A.
1.25;
W.D.
0.1mm;
spring-loaded.
For
use
with
PH3
Phase
Annulus.
32

Other manuals for Olympus bx40

Related product manuals