61
Before use
Waveform ............................................................................Continuous sinusoidal, modulated
Crest factor
1)
.................................................................................................................. 5 to 6.5
Range of power levels
2)
............................................................................................1 to 120 W
Effect levels ...................................................................................................................... 1 to 3
Maximum output voltage at effect level 1 ..................................................................... 1270 V
p
Maximum output voltage at effect level 2 ..................................................................... 1495 V
p
Maximum output voltage at effect level 3 ..................................................................... 2000 V
p
Maximum output current .................................................................................................. 1.2 A
Rated load ....................................................................................................................... 500 Ω
PowerCoag
Supercial coagulation with increased dissection capabilities.
Waveform ............................................................................Continuous sinusoidal, modulated
Crest factor
1)
.................................................................................................................. 3.5 to 6
Range of power levels
2)
............................................................................................1 to 120 W
Effect levels ...................................................................................................................... 1 to 3
Maximum output voltage at effect level 1 ..................................................................... 1224 V
p
Maximum output voltage at effect level 2 ..................................................................... 1519 V
p
Maximum output voltage at effect level 3 ..................................................................... 2000 V
p
Maximum output current .................................................................................................. 1.2 A
Rated load ....................................................................................................................... 500 Ω
SoftCoag
Slow coagulation for deep tissue effects.
Waveform ........................................................................Continuous sinusoidal, unmodulated
Crest factor
1)
............................................................................................................... 1.3 to 1.8
Range of power levels
2)
............................................................................................1 to 200 W
Effect levels ...................................................................................................................... 1 to 5
Maximum output voltage at effect level 1 ....................................................................... 150 V
p
Maximum output voltage at effect level 2 ....................................................................... 176 V
p
Maximum output voltage at effect level 3 ....................................................................... 198 V
p
Maximum output voltage at effect level 4 ....................................................................... 221 V
p
Maximum output voltage at effect level 5 ....................................................................... 235 V
p
Maximum output current .................................................................................................. 3.2 A
Rated load ......................................................................................................................... 50 Ω
Spray
Spark generation allows contact-free supercial coagulation.
Waveform ............................................................................Continuous sinusoidal, modulated
Crest factor
1)
.................................................................................................................. 7.5 to 9
Range of power levels
2)
............................................................................................1 to 120 W
Effect levels ............................................................................................................................. 1
Maximum output voltage at effect level 1 ..................................................................... 4300 V
p
Maximum output current .................................................................................................. 0.8 A
Rated load ....................................................................................................................... 500 Ω
SprayCoag
Spark generation allows contact-free supercial coagulation.
Waveform ............................................................................Continuous sinusoidal, modulated
Crest factor
1)
.................................................................................................................. 7.5 to 9
Range of power levels
2)
............................................................................................1 to 120 W
Effect levels ...................................................................................................................... 1 to 3
Maximum output voltage at effect level 1 ..................................................................... 2520 V
p
Maximum output voltage at effect level 2 ..................................................................... 4300 V
p
Maximum output voltage at effect level 3 ..................................................................... 4300 V
p