Getting Started with CT Analyzer & CT SB2
6 OMICRON
1.4 Power supply
Supply the CT Analyzer only from a power outlet that is equipped with protective ground (PE). Instead
of supplying the CT Analyzer from phase-neutral, it may also be supplied from phase-phase. However,
the voltage must not exceed 240V AC.
1.5 Orderly measures
The CT Analyzer User Manual or alternatively the e-book has always to be available on the site where
the CT Analyzer is being used.
The users of the CT Analyzer must read this manual before operating the device and observe the safety
instructions and all relevant instructions for connection and operation.
The CT Analyzer and its accessories may be used only as described in this User Manual. Any other use
is not in accordance with the regulations. The manufacturer and the distributor are not liable for damage
resulting from improper usage. The user alone assumes all responsibility and risk.
Following the instructions provided in this User Manual is also considered part of being in accordance
with the regulations.
Opening the CT Analyzer or the accessories invalidates all warranty claims.
1.6 Disclaimer
If the equipment is used in a manner not specified by the manufacturer, the protection provided by the
equipment may be impaired. The manufacturer and the distributor are not liable if the safety instructions
given in this manual or any of the relevant international, national, company-internal or local safety
standards and rules are not observed.
1.7 Compliance statements
Declaration of conformity (EU)
The equipment adheres to the guidelines of the council of the European Community for meeting the
requirements of the member states regarding the electromagnetic compatibility (EMC) directive, the low
voltage directive (LVD) and the RoHS directive.
FCC compliance (USA)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant
to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omicron CT Analyzer and is the answer not in the manual?

Omicron CT Analyzer Specifications

General IconGeneral
TypeCT Analyzer
Measurement CategoriesCAT III 300 V
Power Supply100-240 V AC, 50/60 Hz
Primary ApplicationTesting and calibrating current transformers
InterfaceUSB, Ethernet
StandardsIEC 60044-1
Voltage Range0 to 300 V
Accuracy±0.02%
Basic Accuracy0.02% (typical)