EasyManua.ls Logo

Omnitronix Data-Link DL100 - Setup Commands

Default Icon
59 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Omnitronix DL100 User’s Manual
Page 44
Restore all available (that is, not overwritten) cleared records in the current database file. Displays
number of records restored.
Command: RL Function: RELEASE DATA
Syntax: RL
Release records or data in active file.
Command: RLMODE Function: SELECT POLLING MODE
Syntax: RLMODE LINE|Xmodem|CBB
Set data polling method.
Command: TAG Function: TOGGLE LINE NUMBERS
Syntax: TAG [ON|OFF]
Enable/disable addition of line numbers to records as they are output, or display current state.
Command: WAIT Function: TOGGLE WAIT FOR NEXT COMMAND
Syntax: WAIT [ON|OFF]
Enable/disable waiting for NEXT command to release data, or display current state.
6.3 - Setup Commands
The following settings are accessible only with administrative privileges.
Command: DEFAULT Function: RESTORE FACTORY DEFAULTS
Syntax: DEFAULT
Resets all settings to factory default values, except does not change the following settings:
IP address
Subnet mask
Router address
Serial port baud rate and data format
Data alarm fields
Data alarm settings
Action queue