Omnitronix DL100 User’s Manual
Page 46
Command: PUSHTEST Function: TEST FTP PUSH
Syntax: PUSHTEST
Attempt to connect to the FTP server specified in FTP push settings, and display the results of the
attempt.
Command: WRAP Function: SWITCH WRAP MODE
Syntax: WRAP
Change wrap mode for current database file.
Command: ZAP Function: CLEAR UNIT
Syntax: ZAP
Clear all data, and restore all settings to factory default values. Records are recoverable. Requires
confirmation if "Confirm Before Deletion" menu option is enabled.
Command: ZERO Function: EMPTY UNIT
Syntax: ZERO
Clear all data in the database. Records are recoverable. Requires confirmation if “Confirm Before
Deletion” option is enabled.