F-16 Enclosed Switch D4C
Characteristics
Note 1. The above figures are initial values.
2. The values are calculated at an operating temperature of 5°C to 35°C, and an operating humidity of 40% to 70%. Contact your OMRON
sales representative for more detailed information on other operating environments.
Operating Characteristics
Degree of protection IP67
Durability (see note 2) Mechanical: 10,000,000 operations min.
Electrical: 200,000 operations min. (5A at 250 VAC, resistive load)
Operating speed 0.1 mm to 0.5 m/s (in case of plunger)
1 mm to 1 m/s (in case of roller lever)
Operating frequency Mechanical: 120 operations/min
Electrical: 30 operations/min
Rated frequency 50/60 Hz
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance (initial) 250 m max. (initial value with 2-m VCTF cable)
300 m max. (initial value with 3-m VCTF cable)
400 m max. (initial value with 5-m VCTF cable)
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal part and ground, and between each
terminal and non-current-carrying metal part, Uimp: 2.5 kV (EN60947-5-1)
Rated insulation voltage (U
i
) 300 V (EN60947-5-1)
Switching overvoltage 1,000 VAC, 300 VDC max. (EN60947-5-1)
Pollution degree
(operating environment)
3 (IEC60947-5-1)
Short-circuit protective device (SCPD) 10 A fuse type gG (IEC269)
Conditional short-circuit current 100 A (EN60947-5-1)
Conventional enclosed thermal current
(I
the
)
5 A, 4 A, 0.5 A (EN60947-5-1)
Protection against electric shock Class I (with grounding wire)
Vibration resistance Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
Destruction: Approx. 1,000 m/s
2
min.
Malfunction: Approx. 500 m/s
2
min.
Ambient temperature (see note) Operating: –10°C to 70°C (with no icing)
Ambient humidity Operating: 95% max.
Weight With 3-m VCTF cable: 360 g; With 5-m VCTF cable: 540 g
Model D4C-@@01
D4C-@001-@K1EJ@
D4C-@@31
D4C-@031-@K1EJ@
D4C-@@02
D4C-@002-@K1EJ@
D4C-@@32
D4C-@032-@K1EJ@
D4C-@@03
OF max. 11.77 N 17.65 N 11.77 N 17.65 N 11.77 N
RF min. 4.41 N 4.41 N 4.41 N 4.41 N 4.41 N
PT max. 1.8 mm 1.8 mm 1.8 mm 1.8 mm 1.8 mm
OT min. 3 mm 3 mm 3 mm 3 mm 3 mm
MD max. 0.2 mm 0.2 mm 0.2 mm 0.2 mm 0.2 mm
OP 15.7±1 mm 24.9±1 mm 28.5±1 mm 34.3±1 mm 28.5±1 mm
TT (5) mm (5) mm (5) mm (5) mm (5) mm
Model D4C-@@33 D4C-@@10 D4C-@@50 D4C-@@20
D4C-@@27-P
(see note 1)
D4C-@@29-P
(see note 1)
D4C-@@24
D4C-@@24-P
D4C-@024-@K1EJ@
OF max. 17.65 N 11.77 N 1.47 N 5.69 N 5.69 N
RF min. 4.41 N 4.41 N --- 1.47 N 1.47 N
PT max. 1.8 mm 1.8 mm 15° 25° 10±3°
OT min. 3 mm 3 mm --- 40° 50°
MD max. 0.2 mm 0.2 mm --- 3° 3°
OP 34.3±1 mm 28.5±1 mm --- --- ---
TT (5) mm (5) mm --- (70°)(70°)