EasyManua.ls Logo

Omron E2C - Sensor Head Specifications; Key Sensor Head Parameters

Omron E2C
24 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
E2C
E2C
2
Specifications
Sensor Heads
Model E2C-CR5B E2C-CR8A
E2C-CR5B
E2C-X1A
E2C-C1A
E2C-
X1R5A
E2C-X2A E2C-X5A E2C-X10A E2C-
C20MA
Sensing object
Magnetic metals (Refer to
Engineering Data
for non-magnetic metals.)
Standard sensing
object
Iron:5x5x
1mm
Iron: 5 x 5
x1mm
Iron: 5 x 5
x1mm
Iron: 8 x 8
x1mm
Iron: 12 x
12 x 1 mm
Iron: 18 x
18 x 1 mm
Iron: 30 x
30 x 1 mm
Iron: 50 x
50 x 1 mm
Stable sensing range
(within rated
temperature range)
0to0.5mm 0to
0.8 mm
0to1mm 0to
1.5 mm
0to2mm 0to5mm 0to10mm 0to20mm
Safety sensing range
(0
!
Cto40
!
C)
0to0.7mm 0to
1.2 mm
0to
1.5 mm
0to2mm 0to
2.5 mm
0to7mm 0to15mm 0to28mm
Maximum operating
distance (at 23
!
C)
1.2 mm 1.8 mm 2mm 3mm 5mm 10 mm 18 mm 50 mm
Response frequency
(see note 1)
1kHz 800 Hz 350 Hz 100 Hz 50 Hz
Ambient temperature
Operating:
-- 1 0
!
Cto
55
!
C
Operating: --25
!
Cto70
!
C (with no icing)
Ambient humidity
Operating: 35% to 95%
Temperature
influence
"
25% max.
of the sens-
ing dis-
tance at
23
!
Cina
tempera-
ture range
of --10
!
C
and 55
!
C
"
15% max. of the sensing distance at 23
!
C in a temperature range of --25
!
C and 70
!
C
Vibration resistance
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hrs each in X, Y, and Z directions
Shock resistance
Malfunction: 500 m/s
2
(approx. 50G) for 3 times each in X, Y, and Z directions
Enclosure rating
IEC IP64 IEC IP67
Cable length (see
note 2)
3-m
shielded
cable
3-m high-frequency coaxial cable (5 m
max.)
3-m high-frequency coaxial cable (10 m max.)
Weight (with 3-m
cable)
Approx.
10 g
Approx.
40 g
Approx.
45 g
Approx.
50 g
Approx.
60 g
Approx.
140 g
Approx.
270 g
Approx.
300 g
Material
Case
Stainless steel Brass
Sensing
surface
ABS resin
Cable
Polyethylene
Note:
1. Response frequencies are minimum values applicabletoDCsolid-state control output usedto measure standard sensing objects,
each separated from one another with a distance that is double the side dimension of the sensing object and located at a distance
that is half the maximum sensing distance.
2. The cablelengthvaries with the AmplifierUnitandSensorHeadincombination. Refertothe table on the next page. The character-
istic impedance of the coaxial cable is 50
#
.

Related product manuals