A-423E3X-DA-N
E3X-DA-N
Rating/Performance
Amplifier units
Prewired
Type
Standard
models
Monitor-out-
put models
Mark-detecting models
Infrared
models
Water-resis-
tant models
Twin-output
models
Model
NPN
output
E3X-DA11-N E3X-DA21-N E3X-DAB11-N
E3X-DAG11-N
E3X-DAH11-N
E3X-DA11V
E3X-DA11TW
Item
PNP
output
E3X-DA41-N E3X-DA51-N E3X-DAB41-N
E3X-DAG41-N
E3X-DAH41-N
E3X-DA41V
E3X-DA41TW
Light source
(wave length)
Red LED (660 nm)
Blue LED
(470 nm)
Green LED
(525 nm)
Infrared LED
(870 nm)
Red LED (660 nm)
Power supply voltage
12 to 24 VDC ±10%, ripple (p-p) : 10% max.
Power consumption
Normal: Power consumption 960 mW max. (power consumption 40 mA max. at supply voltage 24 V) Eco
mode: Power consumption 720 mW max. (power consumption 30 mA max. at supply voltage 24 V) Digital
display OFF: Power consumption 600 mW max. (power consumption 25 mA max. at supply voltage 24 V)
Con-
trol
output
ON/OFF output
Load current 50 mA (residual voltage NPN/PNP: 1 V max. each) Open collector output type (depends on the
NPN/PNP output format) Light-ON/Dark-ON, switch selectable
Monitor output
---
1 to 5 VDC,
load 10 k
min.
---
Protective circuits
Reverse polarity protection, output short-circuit protection, mutual interference prevention (possible for up to
10 amplifiers)
Re-
spons
e time
Super-high-
speed mode:
0.25 ms for operation and reset respectively
0.5 ms for
operation
and reset
respectively
Standard mode:
Operation/reset: 1 ms each
2 ms for
operation
and reset
respectively
Super-long-dis-
tance mode:
4 ms for operation and reset respectively
7 ms for
operation
and reset
respectively
Sensitivity setting
Teaching or manual method
Func-
tions
Timer functions
OFF delay 0 to 200 ms (1 to 20: 1 ms increments, 20 to 200 ms: 5 ms increments), when the Mobile Control
is used, select either OFF delay, ON delay or one shot.
Automatic pow-
er control (APC)
Fiber-optic current digital con-
trol
---
Fiber-optic current digital
control
Zero reset
Yes (negative indication possible)
Initial reset
Yes (setting conditions initialized)
Monitor focus
---
Upper and
lower limit val-
ues of output
range can be
set per digital
value of 100
---
Indicator lamp
Operation indicator (orange), 7-segment digital incident level display (red), 7-segment digital incident level
percent display (red), incident level & threshold value double-bar display (green, red), 7-segment digital
threshold value display (red)
Display timing
Normal/peak hold/bottom hold selectable
Display direction
Normal/reverse selectable
Optical axis adjustment
function
Yes (hyper flashing emission function)
Ambient lighting
Incandescent lamp: 10,000 lux max. Sunlight 20,000 lux max.
Ambient temperature
Operating: Groups of 1 to 3 amplifiers: -25 to +55°C, Groups of 4 to 11 amplifiers: -25 to +50°C, Groups of
12 to 16 amplifiers: -25 to +45°C Storage: -30 to +70°C (with no icing and condensation)
Ambient humidity
Operating/Storage: 35% to 85% RH (with no condensation)