E5jJ
E5jJ
2
E5CJ
Item
Standard type Single-function type
T
wo alarm points; one event input
T
wo alarm points; without event
input
W
ithout alarm and event input
Relay
output
Voltage
output
Current
output
Relay
output
Voltage
output
Current
output
Relay
output
Voltage
output
Current
output
Model E5CJ-R2HB E5CJ-Q2HB E5CJ-C2B E5CJ-R2 E5CJ-Q2 E5CJ-C2 E5CJ-R E5CJ-Q E5CJ-C
Note:
Be sure to specify Current T
ransformer as necessary when ordering E5CJ-R2HB and E5CJ-Q2HB.
The heater burnout alarm is not available for models other than E5CJ-R2HB and E5CJ-Q2HB.
Current Transformers (CT) (Order Separately)
Hole
diameter
5.8 mm 12.0 mm
Model E54-CT1 E54-CT3
Note:
No CT is required unless the heater burnout alarm function is used.
Terminal Covers (Order Separately)
Model E5AJ E5EJ E5CJ
Connectable
models
E53-COV02 E53-COV03 E53-COV04
Temperature Ranges
Input
(switch selectable)
Temperature-resistance
thermometer
Thermocouple
()
JPt100
Platinum
resistance
thermometer
Pt100
Platinum
resistance
thermometer
K
(CA)
Chromel vs.
alumel
J (IC)
Iron vs.
constantan
T (CC)
Copper vs.
constantan
L
Iron vs.
constantan
U
Copper vs.
constantan
N
Nichrosil
vs. nisil
Built-in
switch
Default set-
ting; 2(K)
T
emperature range
1,300
900
800
600
400
300
200
100
0
–100
–200
°C
–199.9
650.0
–199.9
650.0
–200
1,300
–100
850
–199.9
400.0
–100
850
–199.9
400.0
–200
1,300
Setting
No.
0 1 2 3 4 5 6 7
Minimum
setting unit
Target
value
0.1°C 1°C 1°C 0.1°C 1°C 0.1°C 1°C
g
Alarm 0.1°C 1°C 1°C 0.1°C 1°C 0.1°C 1°C
Note:
Default setting: 2 (K).