Advanced Function Setting Level Section 5-7
• In the operation level or adjustment level, the display automatically
returns to the PV/SP if there are no key operations for the time set for this
parameter.
• The automatic display return time is disabled when the parameter is set to
OFF. (In that case, the display will not be automatically switched.)
• When a parameter is set to ON, once the alarm function has turned ON it
is held until the power is turned OFF. The latch can be canceled, how-
ever, by switching to the initial setting level, communications setting level,
or advanced function setting level.
• If alarm outputs are set to “close in alarm,” the outputs are kept closed. If
they are set to “open in alarm,” they are kept open.
Related Parameters
Alarm value 1 to 3: Page 101 to 102, Alarm value upper limit 1 to 3: Page 103
to 104, Alarm value lower limit 1 to 3: Page 103 to 104 (operation level)
Alar
m 1 to 3 type (initial setting level): Page 124 to 126
Standby sequence reset: Page 133, Alarm 1 to 3 open in alarm: Page 134,
Alarm 1 to 3 hysteresis: Page 135
(advanced function setting level)
ret Automatic Display Return Time
Setting range Unit Default
OFF, 1 to 99 Second off
Function
Setting
a1lt Alarm 1 Latch
Alarm 1 must be assigned, and the
alarm 1 type must not be 0.
a2lt Alarm 2 Latch
Alarm 2 must be assigned, and the
alarm 2 type must not be 0.
a3lt Alarm 3 Latch
Alarm 3 must be assigned, and the
alarm 3 type must not be 0.
Setting range Default
on: Enabled, off: Disabled off
Function
Setting