Omron E5CC Specifications

General IconGeneral
Number of Display Digits4 digits
Number of Control Outputs1
Control MethodON/OFF
Input TypeThermocouple, RTD, Analog voltage, Analog current
Supply Voltage100 to 240 VAC
Output TypeRelay, Voltage, Current
Display TypeLCD
Size48 x 48 mm
Mounting MethodPanel mount
Control OutputRelay, Voltage, Current
Alarm OutputRelay
CommunicationRS-485
Ambient Operating Temperature-10 to 55°C
Ambient Operating Humidity25% to 85% RH
Protection RatingIP66

Summary

Digital Temperature Controllers User's Manual

Application Considerations

Safety Precautions

Precautions for Safe Use

Installation Precautions

Precautions for Operation

Preparations for Use

1-2 I/O Configuration and Model Number Legend

2 Preparations

2-1 Installation

Covers all aspects of physical installation, including dimensions and mounting.

2-2 Using the Terminals

Detailed guide on connecting wires to the terminal blocks for various models.

3 Part Names and Basic Procedures

4 Basic Operation

4-3 Setting the Input Type

Details how to configure the controller for different sensor inputs.

4-9 Determining PID Constants

Methods for calculating or setting PID control constants.

4-10 Alarm Outputs

Configuration of alarms using auxiliary outputs or control outputs.

5 Advanced Operations

5-3 Executing Heating/Cooling Control

Setting up and performing heating and cooling control operations.

5-7 Using the Key Protect Level

Securing the controller settings by restricting access via front panel keys.

5-11 Loop Burnout Alarm (LBA)

Detecting errors in the control loop, such as when the heater fails.

5-12 Performing Manual Control

Procedures for manually controlling the process variable.

6 Parameters

6-2 Protect Level

Details the four levels of protection for parameters and key operations.

6-4 Adjustment Level

Parameters for PID control, tuning, and heating/cooling adjustments.

6-7 Initial Setting Level

Basic setup parameters including input type, units, and control methods.

6-8 Advanced Function Setting Level

Parameters for advanced features like logic operations, alarms, and tuning.

7 User Calibration

A Appendices

A-4 Error Displays

Lists potential error codes and their meanings and remedies.