Digital Temperature Controllers
User’s Manual
E5@C
H174-E1-14
Appendices
Index
Preparations
Introduction
Advanced
Operations
Basic
Operation
Part Names and
Basic Procedures
User Calibration
Parameters
1
2
3
4
5
6
7
A
I

Table of Contents

Other manuals for Omron E5CC

Questions and Answers

  • J
    John JordanAug 30, 2025
    What to do if the temperature is not rising on my Omron Temperature Controller?
    • R
      Robert PhillipsAug 30, 2025
      If the temperature isn't rising on your Omron Temperature Controller, it might be due to the specified operation being unsuitable for the required control. The default is reverse operation, so select either forward or reverse operation depending on what you need. Also, check the heater for burnout or deterioration.
  • A
    Amanda GarrettAug 29, 2025
    Why is my Omron E5CC overshooting, undershooting, or hunting?
    • S
      Sharon PadillaAug 29, 2025
      Overshooting, undershooting, or hunting can occur with the Omron Temperature Controller if ON/OFF control is enabled. To resolve this, select PID control and execute either ST (self-tuning) or AT (auto-tuning). When using self-tuning, turn ON the power supply to the Digital Controller and load (heater, etc.) at the same time, or turn ON the load power supply first. Also, check if the control period is too long compared to the speed of temperature changes and shorten it if necessary. Unsuitable PID constants can also cause this issue; set appropriate PID constants using either autotuning or manual settings. Finally, investigate any errors detected by the HS alarm function and use breeder resistance if leakage current is the problem.
  • Y
    yduffyAug 28, 2025
    Why are communications not possible with my Omron Controller?
    • J
      Jesse MooreAug 28, 2025
      Communications issues with your Omron Controller may arise if a non-recommended adapter is being used. Ensure that the connected device is not faulty.
  • L
    leonyangAug 27, 2025
    Why aren't the set points or RUN/STOP status changing for slaves on my Omron E5CC?
    • C
      Connie StevensAug 27, 2025
      If the set points or the RUN/STOP status will not change for any of the slaves, check that: * The wiring to the master (i.e., the Controller with communications unit number 0) is not correct. * The communications settings in the master are not correct.
  • N
    Nicholas KiddAug 26, 2025
    Why can't I always change set points on my Omron E5CC?
    • J
      Justin HarrisAug 27, 2025
      If it's sometimes not possible to change the set points or RUN/STOP status on your Omron Temperature Controller, there may be noise interference. Connect terminating resistance to both ends of the communications line.
  • N
    Nancy RiceAug 25, 2025
    How to prevent Omron E5CC communication data corruption due to environmental noise?
    • R
      Ryan BlairAug 26, 2025
      If the communications data is being corrupted by noise, try using a slower baud rate. Also, separate the communications cable from the source of the noise.
  • B
    Brooke SandersAug 25, 2025
    How to fix a large temperature error (S.Err display) on my Omron E5CC Temperature Controller?
    • J
      Jane HarveyAug 25, 2025
      A large temperature error or an input error (S.Err display) on your Omron Temperature Controller can be caused by an input type mismatch. Check the sensor type and reset the input type correctly. It can also be caused by the thermometer not being installed properly. Check the thermometer installation location and polarity and install correctly.

Summary

Digital Temperature Controllers Users Manual

Application Considerations

Safety Precautions

Precautions for Safe Use

Installation Precautions

Precautions for Operation

Preparations for Use

1-2 I;O Configuration and Model Number Legend

2 Preparations

2-1 Installation

Covers all aspects of physical installation, including dimensions and mounting.

2-2 Using the Terminals

Detailed guide on connecting wires to the terminal blocks for various models.

3 Part Names and Basic Procedures

4 Basic Operation

4-3 Setting the Input Type

Details how to configure the controller for different sensor inputs.

4-9 Determining PID Constants

Methods for calculating or setting PID control constants.

4-10 Alarm Outputs

Configuration of alarms using auxiliary outputs or control outputs.

5 Advanced Operations

5-3 Executing Heating;Cooling Control

Setting up and performing heating and cooling control operations.

5-7 Using the Key Protect Level

Securing the controller settings by restricting access via front panel keys.

5-11 Loop Burnout Alarm (LBA)

Detecting errors in the control loop, such as when the heater fails.

5-12 Performing Manual Control

Procedures for manually controlling the process variable.

6 Parameters

6-2 Protect Level

Details the four levels of protection for parameters and key operations.

6-4 Adjustment Level

Parameters for PID control, tuning, and heating/cooling adjustments.

6-7 Initial Setting Level

Basic setup parameters including input type, units, and control methods.

6-8 Advanced Function Setting Level

Parameters for advanced features like logic operations, alarms, and tuning.

7 User Calibration

A Appendices

A-4 Error Displays

Lists potential error codes and their meanings and remedies.

Omron E5CC Specifications

General IconGeneral
Number of Display Digits4 digits
Number of Control Outputs1
Control MethodON/OFF
Input TypeThermocouple, RTD, Analog voltage, Analog current
Supply Voltage100 to 240 VAC
Output TypeRelay, Voltage, Current
Display TypeLCD
Size48 x 48 mm
Mounting MethodPanel mount
Control OutputRelay, Voltage, Current
Alarm OutputRelay
CommunicationRS-485
Ambient Operating Temperature-10 to 55°C
Ambient Operating Humidity25% to 85% RH
Protection RatingIP66