91
In the [Data setting] tab, set
the unit No. to the “3 Vision
Master Calibrationto check the
relationship between the
camera coordinate system and
robot coordinate system got
from the calibration.
* Regarding the robot base
coordinate system shown on
the right figure, set the
“Rotation at the “Standard
axis on the “Display setting
tab in the “Calibration support
toolto “Anticlockwise”.
If the relation such as directions
and camera coordinate origin
position between the camera
and the robot flange coordinate
systems is same as the actual
system configuration, the
calibration has succeeded.
* Like the NG example, if the
relation between the camera
and the robot flange coordinate
systems is different, the
calibration has failed. Review
the camera settings, model
registration, and environment
of lightings and then execute
the calibration again.
Camera
OK
NG