No.20S046-00
49/62
FS-C4KU7DGES-F / FS-C4KU7DGES-M42 / FS-C2KU7DGES-F / FS-C2KU7DGES-M42 / FS-C2KU7DGES-C
Product Specifications and Use’s Guide
Name Description
DeviceLinkSelector Selects which Link of the device to control.
DeviceLinkSpeed [DeviceLinkSelector] Indicates the speed of transmission negotiated on the specified Link.
DeviceLinkHeartbeatTimeout
[DeviceLinkSelector]
Controls the current heartbeat timeout of the specific Link.
DeviceLinkCommandTimeout
[DeviceLinkSelector]
Indicates the command timeout of the specified Link.
DeviceStreamChannelCount Indicates the number of streaming channels supported by the device.
DeviceStreamChannelSelector Selects the stream channel to control.
DeviceStreamChannelType
[DeviceStreamChannelSelector]
Reports the type of the stream channel.
DeviceStreamChannelLink
[DeviceStreamChannelSelector]
Index of device’s Link to use for streaming the specifed stream
channel.
DeviceStreamChannelEndianness
[DeviceStreamChannelSelector]
Endianness of multi-byte pixel data for this stream.
DeviceStreamChannelPacketSize
[DeviceStreamChannelSelector]
Specifies the stream packet size, in bytes, to send on the selected
channel for a Transmitter or specifies the maximum packet size
supported by a receiver.
DeviceEventChannelCount Indicates the number of event channels supported by the device.
DeviceCharacterSet Character set used by the strings of the device's bootstrap registers.
DeviceReset Resets the device to its power up state.
DeviceRegistersStreamingStart Prepare the device for registers streaming without checking for
consistency.
DeviceRegistersStreamingEnd Announce the end of registers streaming.
DeviceRegistersEndianness Endianness of the registers of the device.
DeviceTemperatureSelector Selects the location within the device, where the temperature will be
measured.
DeviceTemperature
[DeviceTemperatureSelector]
Device temperature in degrees Celsius (C).
TimestampReset Resets the current value of the device timestamp counter.
TimestampLatch Latches the current timestamp counter into Timestamp Latch Value.
TimestampLatchValue Returns the latched value of the timestamp counter.
DeviceUserMemory Read / Write the user data from / to the non-volatile memory.

Table of Contents