procedure on page 33.
Settings that cannot be performed with the DIP switch are performed with the operation keys.
*2
*3
*7
*3. When using as a dual counter
Note: Displayed only when the output mode is C, R, K-1, P,
Q, A, or K-2.
Note: Not displayed when the H7AN compatibility function is ON.
Note: Not displayed when the H7AN compatibility function is ON.
* The display shows 5 kHz, but the maximum counting speed is 10 kHz.
*1
*7. Set the number for each digit with the Keys.
*5 *5 *5 *5 *5
Note: Displayed only when Twin Counter Mode is not selected.
*5. Displayed for output modes other than K-2, D, L, and H only.
*6.
k-2
,
d
,
l
and
h
are displayed only when the H7AN compatibility
function is
off
or the input mode is
ud-a
,
ud-b
, or
ud-c
.
(Not displayed when the function is set to twn.)
H is displayed only for 2-stage models.
The 5ub parameter is normally
not displayed. You must set the
outm parameter shown below in
advance to
*
6 (k-2, d, l, or h)
to display it.
Usage as a Decrementing
Counter (5ub)
Input mode
Output time
Output 2
time
(OTM2)
Output 1
time
(OTM1)
Dual count
calculating mode
(ADD)
Output mode
(CNTM)
(OUTM)
(OTIM)
(CNTS)
(IFLT)
(DP)
(PSCL)
Min. reset
period
(1 ms)(20 ms)
No decimal
point
One digit after
decimal point
Two digits after
decimal point
Three digits after
decimal point
Decimal point
position
Prescale
value
Counting
speed
(30 Hz) (5 kHz)*
(PNP
input)
(NPN
input)
The characters displayed in reverse video are the default settings.
When performing settings with operation keys only, turn OFF pin 1 of the DIP switch (factory setting).
If pin 1 of the DIP switch is ON, the setting items indicated by will not be displayed.
3 s min.3 s min.
(N)
(0.50 s) (99.99 s)(0.01 s)
(0.50 s)(99.99 s)(0.01 s)
Output 2
time
(OTM2)
(0.01 s) (99.99 s)
(Outputs held)
(F) (C) (R) (K-1) (P) (Q) (A) (K-2) (D) (L) (H)
*6 *6 *6 *6
(Addition)(Subtraction)
(99.999) (1.000)(0.001)
(0.50 s) (99.99 s)(0.01 s)
*4
Up
Up
Up
Up
Up
Up
Up
Up
Up
Up
Note: Displayed only when the
output mode is C, R,
K-1, P, Q, A, or K-2.
Note 1: Displayed for output
modes other than D, L,
and H.
Note 2: HOLD cannot be set
when the output mode
is K-2.
Note: Displayed only when the
output mode is C, R, K-1,
P, Q, A, or K-2.
*4. Displayed only when the output
mode is K-2, D, L, or H.
NPN/PNP
input mode
(IMOD)
(DOWN)
(UP/DOWN A) (UP/DOWN B) (UP/DOWN C) (UP/DOWN D) (UP/DOWN E) (UP/DOWN F)
(UP)
Power ON
Run mode
Function setting mode
up
down ud-a ud-b ud-c
ud-d ud-e ud-f
0.500.01 99.99
0.500.01 99.99
30hz 5khz
20ms 1ms
· Set the input mode with any of the Keys.
· Set the output mode with any of the Keys.
· Set the number for each digit with the Keys.
·
Set the dual count calculating mode
the Key.
· Set the NPN/PNP input mode with any of the Keys.
· Set the counting speed with any of the Keys.
· Set the min. reset input signal width with any of the Keys.
· Set the decimal point position with any of the Keys.
· Set the number for each digit with the Keys.
● 2-stage Preset Counter
● Batch Counter
● Twin Counter
If the output time is 0.00,
hold is displayed.
*1. If the mode is switched to the function setting mode during operation, operation will continue.
*2. Changes made to settings in function setting mode are enabled for the first time when the mode is
changed to run mode. Also, when settings are changed, the counter is reset (present value initialized
and output turned OFF) on returning to run mode.
Note:Displayed only when the
output mode is C, R, K-1, P,
Q, or A.
Note:Displayed only when the
output mode is C, R, K-1, P,
Q, or A.
(0.50 s) (99.99 s)(0.01 s)
Output 2
output
time
(OTM2)
Output 1
output
time
(OTM1)
(0.50 s) (99.99 s)(0.01 s)
To next pageFrom next page
otm2
0.50
otm2
0.50
otm2
0.50
otm1
hold
otm1
hold
iflt
20ms
cnts
30hz
otim
0.50
outm
n
cntm
up
imod
npn
calm
add