2-11
List of Settings Section 2
List of
Settings
K3HB-R/P
Communications Monitoring Settings
Note The values beginning with H' in the Monitor/Setting range column are used when setting or monitor-
ing data via communications.
Protect Level
Note The values beginning with H' in the Monitor/Setting range column are used when setting or monitor-
ing data via communications.
RUN Level
Note The values beginning with H' in the Monitor/Setting range column are used when setting or monitor-
ing data via communications.
Variable
type
Address Parameter
name
Charac-
ter
Monitor/Setting range Character Default
setting
Decimal point Unit
C0 0000
Version --- --- --- --- --- ---
0001
Status --- --- --- --- --- ---
0002
Measurement
value
--- H’FFFFB1E1 to H’0001869F: 19999 to 99999
(Time limit is OFF. Lower limit of P is 0.)
H’00000000 to H’0001869F: 0 to 99999 (Time unit is
min.)
H’00000000 to H’000176D7: 0.00.00 to 9.59.59
(Time unit is hr:min:s.)
H’00000000 to H’0001850F: 00.00.0 to 99.59.9
(Time unit is min:s:ms.)
--- --- --- ---
0003
Max. value --- Same as above --- --- --- ---
0004
Min. value --- Same as above --- --- --- ---
Variable
type
Address Parameter
name
Charac-
ter
Monitor/Setting range Character Default
setting
Decimal point Unit
C1 0000 RUN/adjustment
protect
run.pt H’00000000 to H’00000002: (0 to 2) 0 to 20--- ---
0001 Setting level
protect
set.pt H’00000000 to H’00000002: (0 to 2) 0 to 21--- ---
0002 Setting change
protect
wt.pt H’00000000: OFF (0)
H’00000001: ON (1)
off, on off --- ---
0003 Max/Min protect mmpt H’00000000 to H’00000002: (0 to 2) 0 to 20--- ---
Variable
type
Address Parameter
name
Charac-
ter
Monitor/Setting range Character Default
setting
Decimal point Unit
C2 0000
Measurement
value/comparative
set value HH
--- H’FFFFB1E1 to H’0001869F: 19999 to 99999
(Time limit is OFF. Lower limit of P is 0.)
H’00000000 to H’0001869F: 0 to 99999 (Time unit is
min.)
H’00000000 to H’000176D7: 0.00.00 to 9.59.59
(Time unit is hr:min:s.)
H’00000000 to H’0001850F: 00.00.0 to 99.59.9
(Time unit is min:s:ms.)
:9999 to 99999
0. 00. 00 to 99999
0. 00. 00 to
9. 59. 59
0. 00. 00 to
99. 59. 9
99999 According to the
decimal position
setting. The time
unit, however, is
indicated as
*.**.** for
hr:min:s and
as **.**.* for
min:s:ms.
---
0001 Measurement
value/compara-
tive set value H
--- Same as above Same as above 99999 Same as above ---
0002 Measurement
value/compara-
tive set value L
--- Same as above Same as above R: :9999
P: 0
Same as above ---
0003 Measurement
value/compara-
tive set value LL
--- Same as above Same as above R: :9999
P: 0
Same as above ---

Table of Contents

Other manuals for Omron K3HB-R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron K3HB-R and is the answer not in the manual?

Omron K3HB-R Specifications

General IconGeneral
BrandOmron
ModelK3HB-R
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals