Loading...
Digital Indicators K3HB-X/-V/-H/-S 27
Input Compensation/Display
Forces the present value to 0. (Convenient for setting reference val-
ues or deducting tares for weight measurement.)
Shifts the current value measured with a forced zero to 0 again. It is
possible to measure two or more compounds separately and then, by
releasing the tare zero and forced-zero, measure the combined total.
Compensates for mild fluctuations in input signals due to factors
such as sensor temperature drift, based on OK (PASS) data at mea-
surement. (This function can be used with sampling hold, peak hold,
or bottom hold.)
Changes the display value to 0 for input values less than the set
value. It is enabled in normal mode only. (This function can be used,
for example, to stop negative values being displayed or to eliminate
flickering and minor inconsistencies near 0.)
The display refresh period can be lengthened to reduce flickering
and thereby make the display easier to read.
Values can be displayed in either red or green. With comparative out-
put models, the display color can also be set to change according to
the status of comparative outputs (e.g., green to red or red to green).
The current display value can be selected from the present value, the
maximum value, and the minimum value.
It is possible to specify (i.e., restrict) the values that the smallest dis-
played digit can change by. For example, if the setting is 2, the small-
est digit will only take the values 0, 2, 4, 6, or 8 and if the setting is 5,
it will only take the values 0 or 5. If the setting is 10, it will only take
the value of 0.
Forced-zero
Tare Zero
Zero-trimming
Zero-limit
Display Refresh Period
Display Color Selection
X V S
V S
X V H S
X V H S
Zero-limit
setting
Display
Input
X V H S
X V H S
110.01
Red
Red
Comparative set value L
Comparative set value H
110.00
100.05
110.00
99.87
110.00
L
Example) Setting: grn-r
H
P
Green
Display Value Selection
Step Value
X V H S