Precautions for Safe Use
Test the functionality every six months to detect welded contactor contacts.
The customer is responsible for attaining conformance of the entire system to standards.
To detect electrical and mechanical failures, use a combination of redundant semiconductor
output contacts and redundant mechanical output devices.
Refer to ISO 14119:2013 for additional measures to minimize the possibility of interlocking
devices associated with guards from being disabled.
A-3-3
Safety Laser Scanners
Application Overview
Safety category/PL Safety device Stop category Reset
Equivalent to 3/PLd
(Laser Scanner)
Laser scanner 0 Auto
Emergency stop pushbutton 0 Manual
AGV stops when emergency stop pushbutton S1 is pressed.
AGV stops when laser scanner S3 detects that persons or objects approach into the safety zone.
Appendices
A - 36
NX-series Safety Control Unit User's Manual (Z930)