Program
Precautions for Safe Use
Test the functionality every six months to detect welded contactor contacts.
The customer is responsible for attaining conformance of the entire system to standards.
To detect electrical and mechanical failures, use a combination of redundant semiconductor
output contacts and redundant mechanical output devices.
Refer to ISO 14119:2013 for additional measures to minimize the possibility of interlocking
devices associated with guards from being disabled.
A-3-6
Two-hand Switches
Application Overview
Safety category/PL Safety device Stop category Reset
Equivalent to 4/PLe Two-hand control switch 0 Auto
Motor M operates when two-hand control switches S11 and S12 are pressed at the same time.
Appendices
A - 47
NX-series Safety Control Unit User's Manual (Z930)
A-3 Application Examples
A
A-3-6 Two-hand Switches