S82J
S82J
5
Specifications
Ratings/Characteristics
Item
100
to 240 V
AC input
100 or 200 V
AC
(selected
automatically)
100 or 200 V
AC
(selectable)
10 W 25 W 50 W
100 W
(24 V)
100 W (5,
12, 15 V)
150 W 300 W 600 W
Ef
ficiency (typical)
67% min. (77% min. for 50-W
, 24-V models)
83% min.
75.5%
min.
82% min.
Input
Voltage
100 to 240 V
AC (85 to 264 V
AC)
1
10 to 170 VDC (set the terminal (L) to + side) (see note1)
100 (85 to 132) or 200
(170 to 264) V
AC
(selected
automatically)
100 (85 to 132) or 200
(170 to 253) V
AC
(selectable)
Frequency
50/60 Hz (47 to 450 Hz)
Current
(see note
2)
100 V
AC
input
0.35 A
max.
0.8 A
max.
1.4 A max.
2.5 A
max.
2.5 A
max.
3.5 A
max.
8 A max.
14 A max.
(see
note
2)
200 V
AC
input
0.3 A
max.
0.6 A
max.
0.8 A max.
1.5 A
max.
1.4 A
max.
2.1 A
max.
4 A max. 7 A max.
Leakage
current
(t
100 V
AC
input
0.5 mA max.
current
(see note
2)
200 V
AC
input
1 mA max.
Inrush
current
(
25°C,
100 V
AC
input
25 A max. 30 A max.
(25 C
,
cold start)
(see note
2)
200 V
AC
input
50 A max. 60 A max.
Noise filter
Yes
Output
(see note
3)
V
oltage adjustment
range
±
10% (adjustable with variable resistor (V
. ADJ))
(see
note
3)
Ripple (see note 2)
2% (p-p) max.
Input variation
influence
0.4% max.
Load variation
influence
0.8% max. (with rated input, 10% to 100% load)
T
emperature variation
influence
0.05%/°
C max. (with rated input and output)
Startup time 500 ms max. (up to 90% of output voltage at rated input and output)
300 ms max. (up to
90% of output voltage at
rated input and output)
Hold time (see note 2) 20 ms min.
Additional
function
Overload protection
105% to 160% of rated load current, inverted L drop/intermittent operation type,
automatic reset
105% min. of rated load
current, inverted L drop
type, automatic reset
(For the 600-W model,
the circuit will be shut
OFF when the overload
exceeds 5
±
3 s.
Protection-ON alarm
indicator lit (see note 4))
Overvoltage protection
(see note 5)
No Yes Y
es (5-V
output
models
only)
No Y
es, protection-ON
alarm indicator lit (see
note 4)
Overheat protection
No Yes,
protection-
ON alarm
indicator lit
(see note
4)
Protection-ON alarm
indicator
No Y
es (color
, red)
Parallel operation
No Y
es, 5 units max.
Series operation
No Yes

Other manuals for Omron S82J Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron S82J Series and is the answer not in the manual?

Omron S82J Series Specifications

General IconGeneral
BrandOmron
ModelS82J Series
CategoryPower Supply
LanguageEnglish

Related product manuals