6-12
6-3 Using the Parameter Unit
6
Operation
Alarm Codes and Meanings
Note The following alarms are not recorded in the history.
11: Power supply undervoltage
36: Parameter error
37: Parameter corruption
38: Drive prohibit input error
95: Servomotor non-conformity
96:
LSI setting error
Software Version
Displays the software version of the Servo Drive.
Warning Display
Regeneration Load Ratio
Displays the load ratio as a percentage of the detection level for the regeneration load.
Alarm
codes
Meaning
Alarm
codes
Meaning
11 Power supply undervoltage 29 Deviation counter overflow
12 Overvoltage 34 Overrun limit error
14 Overcurrent 36 Parameter error
15 Built-in resistor overheat 37 Parameter corruption
16 Overload 38 Drive prohibit input error
18 Regeneration overload 48 Encoder phase Z error
21 Encoder disconnection detection 49 Encoder CS signal error
23 Encoder data error 95 Servomotor non-conformity
24 Deviation counter overflow 96 LSI setting error
26 Overspeed Others Other errors
27 Electronic gear setting error
a.-k1k .0k7k
rknk-k-k-k-
-
a
: No warning, : Warning
Overload: 85% or more of the alarm level for
overload.
Over-regeneration: 85% or more of the alarm level for
regeneration overload.
The alarm level will be 10% of the operating ratio of the
regeneration resistance if the Regeneration Resistance
Selection (Pn6C) is set to 1.
Not used.
Not used.
rkgk k8k0.0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SMARTSTEP 2 R7D-BP04H and is the answer not in the manual?

Omron SMARTSTEP 2 R7D-BP04H Specifications

General IconGeneral
BrandOmron
ModelSMARTSTEP 2 R7D-BP04H
CategoryServo Drives
LanguageEnglish

Related product manuals