How-to’s Section 5-1
270
' Unit 0
MECHATROLINK(0,20,65)
MECHATROLINK(0,20,66)
MECHATROLINK(0,20,67)
'Stop MECHATROLINK Section
'================================================
'THIS SECTION MUST BE MANUALLY SET BY THE USER
'ACCORDING TO THE APPLICATION. TYPICAL ACTIONS ARE
'VARIABLE INITIALIZATION, SERVO/AXIS SETTING, NAMING
'GLOBAL VARIABLES AND START THE "APPLICATION" PROGRAM.
'================================================
'Define Names for global variables
GLOBAL "project_status",100
GLOBAL "alarm_status",101
GLOBAL "action",102
'Initialize variables
VR(0)=0
project_status=0
alarm_status=0
action=0
'Start APPLICATION program
RUN "APPLICATION",2
STOP
5-1-2 Gain settings
The gain setting is related to the mechanical system to which the motor is
attached. There are three main concepts:
Inertia ratio
Rigidity
Resonant frequency.
These concepts are described in section 1-10.
This section shows example parameter values for:
Speed Loop Gain
Proportional position gain
Velocity Feed Forward gain.
The example values for the program and motion parameters in the Trajexia
system are given below. Note that they are appropriate for 13-bit encoders
and Sigma-II Servo Drivers.
/i
/i
Drive Parameter value Description
Pn103 = 716 Inertia ratio
Pn110 = 0012 No autotuning
Pn202=1 Gear ratio numerator
Pn203=1 Gear ratio denominator
Motion Parameter values Description
UNITS =1 Working in encoder counts
SPEED=200000 Speed setting
ACCEL=1000000 Acceleration setting