EasyManua.ls Logo

Omron E5EN User Manual

Omron E5EN
141 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
USER MANUAL
Cat. No. H111-E1-2
E5EN
Temperature Controller

Table of Contents

Other manuals for Omron E5EN

Questions and Answers:

Omron E5EN Specifications

General IconGeneral
Size48 x 96 mm
WeightApprox. 300 g
Input TypeThermocouple, RTD, Analog
Output TypeRelay, Voltage, Current
Power Supply Voltage100 to 240 VAC
Display TypeDigital
Number of Control Outputs1
CommunicationRS-485
Ambient Operating Temperature-10 to 55 °C
Ambient Operating Humidity25 to 85% RH

Summary

E5EN Temperature Controller User Manual

Preface

Precautions

Safety Precautions and Signals

Safety Signal Words

Explains the meaning of WARNING and CAUTION signals used in the manual for safety.

General Safety Precautions

Lists important safety rules and guidelines to follow when using the product.

Important Notices

Manual Conventions and Symbols

Meanings of Abbreviations

Defines abbreviations used for parameter names, figures, and text explanations.

How to Read Display Symbols

Explains the correspondence between symbols displayed on the E5EN and their meanings.

Chapter 1 Introduction

Names of Parts

Identifies and describes the components of the E5EN's front panel and display.

I/O Configuration and Main Functions

Explains the input/output configuration and the primary functions of the E5EN controller.

Setup Levels and Key Operations

Details the setup levels and how to operate the front panel keys for configuration.

Communications Function

Describes how to configure and utilize the E5EN's communications function.

Chapter 2 Preparations

Installation

Provides instructions for the physical installation of the E5EN controller.

Wiring Terminals

Details the terminal arrangements and wiring procedures for connecting the E5EN.

Chapter 3 Basic Operation

Initial Setup Examples

Provides step-by-step examples for common initial setup configurations of the E5EN.

Setting the Input Type

Guides on selecting and setting the correct sensor input type for the E5EN.

Selecting Temperature Units (°C/°F)

Explains how to choose between Celsius (°C) and Fahrenheit (°F) for temperature display.

PID or ON/OFF Control Selection

Describes how to select between PID and ON/OFF control methods for the E5EN.

Chapter 4 Applied Operation

Shifting Input Values

Explains how to adjust input values to compensate for sensor characteristics and improve accuracy.

Alarm Hysteresis Settings

Details how to set alarm hysteresis for stable and reliable alarm operation.

Setting Scaling Limits (Analog Input)

Guides on configuring scaling upper and lower limits for analog input signals.

Executing Heating and Cooling Control

Explains how to perform and manage heating and cooling control operations using the E5EN.

Chapter 5 Parameters

Conventions Used in This Chapter

Explains the meaning of icons and conventions used within Chapter 5 for parameter descriptions.

Protect Level

Details how to set and use the protect level to restrict parameter access and prevent unauthorized changes.

Operation Level Parameters

Lists and describes parameters accessible and configurable in the operation level.

Adjustment Level Parameters

Lists and describes parameters accessible and configurable in the adjustment level for fine-tuning.

Initial Setting Level

Guides on configuring basic parameters like input type, scaling, and control modes.

Advanced Function Setting Level

Covers advanced settings including parameter initialization, multi-SP, and event inputs.

Communications Setting Level

Details parameters for configuring communication settings such as baud rate and parity.

Chapter 6 Calibration

Parameter Structure for Calibration

Explains the structure of parameters relevant to the calibration process.

User Calibration Procedures

Guides on performing user calibration for various input types.

Calibrating Thermocouples

Details the specific steps for calibrating thermocouple inputs.

Calibrating Analog Input

Explains the procedure for calibrating analog input signals.

Appendix

Specifications and Ratings

Lists the detailed electrical, environmental, and performance specifications of the E5EN.

Technical Characteristics

Outlines the key technical characteristics, including hysteresis, integral time, and dielectric strength.

Current Transformer (CT) Information

Provides specifications and dimensions for compatible current transformers.

Error Display Codes and Meanings

Explains common error displays, their meanings, and corrective actions.

Parameter Operations List

Lists parameters by level with their settings, display values, and defaults.

Sensor Input Setting and Indication Ranges

Provides comprehensive tables for sensor input settings and their corresponding indication ranges.

Setup Levels Diagram

Offers a visual overview of the E5EN's setup levels and navigation paths.

Parameter Flow

Illustrates the logical flow and relationships between various parameters in the E5EN.

Revision History

Related product manuals