Practical examples Section 5-2
333
FHSPEED=1000.0000
OUTLIMIT=1.0000
FE_RANGE=0.0000
ENDIF
' Variables
' TABLE DATA
'Stop Standard Section
RETURN
5-2-3 Initialization program
The Initialization program sets the parameters for the axes. These parameters
are dependant upon the Motor Encoder resolution and the motor maximum
speed.
'================================================
'EXAMPLE OF INITIALIZATION PROGRAM
'THIS VERSION IS DESIGNED FOR MECHATROLINK-II SERVOS
'ADAPT THIS PROGRAM ACCORDING TO YOUR APPLICATION
'================================================
BASE(x)
restart=0
inertia_ratio=set_load_inertia_ratio
'----------------------------
'EXAMPLE 1
'SGMAH-01AAA61D-OY motor data
'----------------------------
enc_resolution=2^13 '13 bit encoder
max_speed=5000 '5000 rpm max. speed
'----------------------------
'EXAMPLE 2
'SGMAH-01A1A61D-OY motor data
'----------------------------
enc_resolution=2^16 '16 bit encoder
max_speed=5000 '5000 rpm max. speed
'----------------------------
'WRITE PARAMETERS IN THE SERVO
'----------------------------
DRIVE_WRITE($103,2,inertia_ratio) 'Write inertia ratio
DRIVE_READ($110,2,10)
IF VR(10)<>$0012 THEN
DRIVE_WRITE($110,2,$0012,1)
'Pn110=0012h (autotuning disabled)
restart=1
ENDIF
DRIVE_READ($202,2,10)
IF VR(10)<>1 THEN
Note Refer to the Servo Driver and the motor data sheet for this information.