83
RFID System
User's Manual
Section 3
l
Communications Commands
Section 3
Commands
FILL (FL)
This command writes one byte of specified data to the specified memory area of the Data Carrier. The
write data is specified in hexadecimal.
Data setting Always H.
Processing area number
setting
Always 1.
Write area start address Specifies the start address of the area in the Data Carrier to be written to in 4-digit hexadecimal
code.
Setting range: 0000h to 1FFFh
Number of write bytes Specifies the data to be written to the Data Carrier in 2-digit hexadecimal.
Setting range: 00h to FFh (00 = 256 bytes)
Specified data Indicates the data to be written to the Data Carrier.
End code Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.95
Command
××
FL
××
H1
××
211 4
Number of
write bytes
2
××
Specified
data
2
2
CR
Terminator
Command
code
Data
setting
Processing
area
number
setting
Write area
start address
Response
FL
00
22
2
CR
Terminator
Command
code
End code