84
Section 3 Communications Commands
RFID System
User's Manual
Section 3
Commands
•Example
01
01
2F
01
01
01
36
01
002FH
0030H
0031H
0032H
0033H
0034H
0035H
0036H
After Writing
06
Command
code
FL
30
H1
00
Data
setting
Process
area
number
setting
211 4
Number of
write bytes
Write area
start address
2
01
Specified
data
2
2
CR
Terminator
Command
code
FL
00
22
2
CR
Terminator
End code
30
31
2F
32
33
35
36
34
002FH
0030H
0031H
0032H
0033H
0034H
0035H
0036H
Before Writing
Writing 01H to the 06H bytes in the memory area starting from
address 0030H for a Data Carrier in which the same data and
address is written.
Command
Response