91
RFID System
User's Manual
Section 3
l
Controller Control Commands
Section 3
Commands
COMMUNICATIONS CONDITIONS SETTING (TR)
This command is used to set serial communications parameters. The Hand-held Reader Writer must
be restarted to make the changes take effect.
The COMMUNICATIONS CONDITIONS SETTING (TR) command can be used only with the V600-CH1D-V2.
Do not use it with the V600-CHUD.
Baud rate Sets the baud rate.
0: 9,600 bps
1: 2,400 bps
2: 4,800 bps
3: 19,200 bps
4: 38,400 bps
Default setting: 9,600 bps
Data length Sets the data length.
0: 7 bits
1: 8 bits
Default setting: 7 bits
Parity Sets the parity.
0: Even parity
1: Odd parity
2: No parity
Default setting: Even parity
Stop bits Sets the number of stop bits.
0: 2 bits
1: 1 bit
Default setting: 2 bits
End code Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
p.95
Command
TR
1
Data
length
211
2
CR
1
Baud
rate
1
Parity
1
Stop
bits
11
Command
code Terminator
Response
TR
0
2
CR
0
Command
code
2
2
TerminatorEnd code