92
Section 3 Controller Control Commands
RFID System
User's Manual
Section 3
Commands
BASIC FUNCTIONS SETTING (FN)
This command is used to set the Auto Commands OFF function and Normal Operation Output func-
tion. The Hand-held Reader Writer must be restarted to make the changes take effect.
Only the Auto Command OFF function is supported by the V600-CHUD. The Normal Operation Output function is not
supported by the V600-CHUD.
Auto Command OFF
specifications
Designates whether the Auto Command OFF function is used.
0: Auto Command OFF used.
1: Auto Command OFF not used.
Default setting: Auto Command OFF used.
Normal Operation Out-
put Specification
Designates whether the Normal Operation Output is used.
0: Normal Operation Output used.
1: Normal Operation Output not used.
Default setting: Normal Operation Output used.
End code Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
p.95
Command
FN
1
2112
CR
1
Command
code Terminator
Auto
Command
OFF
specification
Normal
Operation
Output
specification
Response
FN
00
22
2
CR
Command
code TerminatorEnd code