93
RFID System
User's Manual
Section 3
l
Controller Control Commands
Section 3
Commands
SET INFORMATION READ (UL)
This command is used to read the settings of the Hand-held Reader Writer.
Only the Auto Command OFF function is supported by the V600-CHUD.
The settings made with the COMMUNICATIONS CONDITIONS SETTING (TR) command are not valid for the V600-
CHUD.
End code Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
p.95
Settings for TR command Baud rate 0: 9,600 bps
1: 2,400 bps
2: 4,800 bps
3: 19,200 bps
4: 38,400 bps
Data length 0: 7 bits
1: 8 bits
Parity 0: Even parity
1: Odd parity
2: No parity
Stop bits 0: 2 bits
1: 1 bit
Settings for FN command Auto Command OFF Specification 0: Auto Command OFF used.
1: Auto Command OFF not used.
Normal Operation Output Specification 0: Normal Operation Output used.
1: Normal Operation Output not used.
System data SI000000
Command
UL
2
2
CR
Command
code
Terminator
Response
UL
××
00
TR
22
×× :FN
×× :
2
CRSI
8
000000
Hand-held Reader Writer system data
Baud
rate
Data
length
Stop
bits
Parity Auto Command
OFF specification
Normal
Operation
Output
specification
Command
code
Terminator
End code
Settings for TR command
Settings for
FN command