CID Read Button
Write Data Designation Area
CID Write Button
Repeat
Communications Results Display Area
Item Description Comments
Offset Specify the CID offset between 0 and 15 bytes.
Length Specify the CID length between 1 and 16 bytes.
Maximum byte of CID Specify the maximum CID length between 1 and 16 bytes.
Write Data Designation
Area
For the write data, specify only the number of bytes for the specified
Length.
Specify only visible ASCII
characters.
Repeat Check this box if the program is to be run repeatedly.
Command Commands actually sent to the amplifier unit are displayed.
Communications Results
Display Area
Transmitted and received data to the amplifier unit are displayed.
TX: The data transmitted toward the amplifier unit is displayed.
RX: The data received from the amplifier unit is displayed.
Execution example
For example, the results display would be as shown below if a CID read was executed with "an offset
of 0, a length of 16, and a maximum bytes of CID of 16".
3 V640 Utility Tool Features
3-7
V640 SERIES CIDRW SYSTEM OPERATION MANUAL V640 Utility Tool (Z469-E1)
3-4 Command Window
3
3-4-1 CID R/W