About Communication Commands
ZFX-C Serial Communication Command Reference
31
Backing up Image Data < IMGSAVE command >
Backing up image data from the Controller to an external device
This command backs up image data from the Controller by XMODEM protocol.
< Command format >
< File transfer >
The image data is transferred by XMODEM (-CRC or SUM) after READY is received. XMODEM (-1K) is not
supported.
< Response format >
< Explanation of parameters >
Save memory No. Specifies the No. of the save memory for backing up the image data to. (0 to 99)
When "-1" is specified for the Save memory No., the latest image data of camera 0 is
specified.
When "-2" is specified for the Save memory No., the latest image data of camera 1 is
specified.
IMGS
C
R
IS
C
R
AVE 00
or
Save
memory No.
(max. 2 digits)
Save
memory No.
(max. 2 digits)
OK
C
R
ER
C
R
R EAD
C
R
Y
When processing ends successfully
When processing fails