EasyManuals Logo

Omron ZFX-C Command Reference

Omron ZFX-C
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #55 background imageLoading...
Page #55 background image
About Communication Commands
ZFX-C Serial Communication Command Reference
53
Brightness and color inspection parameters
Brightness
Hue
Data No. Parameter Output Range
71 Density average upper limit value 0.0 to 255.0
72 Density average lower limit value 0.0 to 255.0
73 Density deviation upper limit value 0.0 to 127.0
74 Density deviation lower limit value 0.0 to 127.0
Data No. Parameter Output Range
51 Deviation 0: OFF, 1:ON
71 Hue upper limit value 0.0 to 360.0
72 Hue lower limit value 0.0 to 360.0
73 Saturation upper limit value 0.0 to 100.0
74 Saturation lower limit value 0.0 to 100.0
75 Value upper limit value 0.0 to 100.0
76 Value lower limit value 0.0 to 100.0
77 Hue deviation upper limit value 0.0 to 180.0
78 Hue deviation lower limit value 0.0 to 180.0
79 Saturation deviation upper limit value 0.0 to 50.0
80 Saturation deviation lower limit value 0.0 to 50.0
81 Value deviation upper limit value 0.0 to 50.0
82 Value deviation lower limit value 0.0 to 50.0