battery charged. Adjust only when plant is stopped. FAN BELT
Avoid overcharging. The resistor is located in the To adjust the fan belt, loosen the nut on the belt
generator air outlet. tightener pulley shaft. Move the shaft left or right in
the elongated slot in pulley mounting bracket until a
If a separate automatic demand control for starting deflection of
1/2-inch
is obtained when about 15
and stopping is used, adjust the charge rate for its pounds of force is applied at a point midway between
maximum 4.5 amperes. This normally keeps battery the fan pulley and belt tightener pulley. Be sure to
charged even if starts occur as often as 15 minutes tighten, nut securely,
apart.
22