OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor for the correct advice before proceeding with the
installation or operation of this product.
Jet Assisted Pumps
1000 Series
JMM100 JS100 JSM100 JSK110
JS110 JSP110 JSK120
JS120 JSP120
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by a
Residual Current Device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.

Questions and Answers

  • P
    Patricia HarveyAug 8, 2025
    What to do if my Onga Water Pump does not start?
    • H
      Heather BurgessAug 8, 2025
      If your Onga Water Pump isn't starting, ensure it's connected to a live outlet. Also, check the circuit breakers and fuses. If the pressure controller detects no water in the tank, make sure there's enough water and press the reset or start button. A blocked pump can also be the cause; disconnect it from the power and inspect the housing and discharge for any obstructions. If none of these steps work, the capacitor may be defective, and you should call a qualified service technician.
  • L
    Laura PattonAug 13, 2025
    Why does my Onga Water Pump have poor performance with low pressure?
    • B
      bradley95Aug 13, 2025
      To troubleshoot low pressure or flow in your Onga Water Pump, first, check the suction line for leaks, especially at the joints. If the tank water level is too far below the pump, consider discussing a better pump option with your Onga dealer or moving the pump closer to the tank. Also, a worn or damaged pump can cause poor performance, so ask your Onga dealer to investigate worn parts.
  • T
    Tamara SantanaAug 20, 2025
    What to do if there is no water from onga JSM100 Water Pump?
    • M
      Mr. Thomas SchultzAug 20, 2025
      If your Onga Water Pump isn't providing water, first ensure the pump body and suction line are filled with water before starting. Check the suction line for leaks, particularly at the joints. Blockages in the pump or discharge can also prevent water flow, so disconnect the pump from power and inspect for foreign matter. Make sure all valves on the tank, pump, and outlets are open. If the tank doesn't have enough water, wait until it refills and then press the reset or start button on the pressure controller. Also, check and clean the pump if it's not producing enough pressure, and inspect/clean any in-line or tap filters that may be blocked. Finally, check system pressure and adjust the pressure switch accordingly.
  • G
    Gina HartAug 27, 2025
    Why does my onga JSM100 Water Pump run intermittently?
    • Z
      zhernandezAug 27, 2025
      If your Onga Water Pump runs intermittently, start by checking for small leaks in your household plumbing and fix them. Ensure that the water temperature remains within the specified limits. Verify that the voltage is within the allowable limits as stated in the specifications, and correct if necessary. Also, make sure there's adequate ventilation for the motor cooling fan.
  • J
    John TapiaSep 1, 2025
    What to do if onga JSM100 will not stop?
    • J
      Jeremy JohnsonSep 1, 2025
      If your Onga Water Pump won't stop, even with no taps open, debris might be caught in the pressure controller; take it to your Onga dealer for service. Also, check for leaks in the household plumbing and fix them.

Summary

Model Data

Application

Installation

Safety and Environmental Considerations

Covers electrical standards, freezing protection, power isolation, fluid compatibility, and fire hazards during installation.

Installation Preparation and Protection

Inspect for damage, protect pump from environment, and ensure suction piping is clear and free of airlocks.

Pipework and Power Connections

Covers pipe installation, pump location, power source requirements, and suction system configuration.

Discharge and Priming Procedures

Details discharge piping setup, pump priming process, and final connection steps before operation.

Electrical Installation and RCDs

Final electrical connection, socket outlet requirements, and recommendation for RCD protection.

Operation

Operational Safety and Warnings

Read manual, ensure water, avoid hazardous fluids/environments, and heed the 'Do Not Run Pump Dry' warning.

Start-up and Priming

Prime pump and suction line, then start operation for JMM, JSM, JSP models as per system pressure.

JSK Model Specific Operation

Details pressure switch setup, aqua packs, and tank recharge procedures specific to JSK models.

Service and Maintenance

Troubleshooting

Notes

Warranty Information

International and Local Terms

Covers warranty duration, coverage, and conditions for Australia/NZ and international consumers.

Warranty Exclusions

Lists conditions not covered by warranty, such as misuse, accidents, unauthorized repairs, and normal wear.

Spare Parts and Service Access

Information on spare parts availability, how to get service, and limitations on equipment accessibility.

Liability Limitations and Legal Rights

Details limitations of Pentair Water's liability and consumer legal rights under the warranty.

onga JSM100 Specifications

General IconGeneral
ModelJSM100
CategoryWater Pump
TypeJet Pump
Voltage220-240V
Frequency50 Hz
Max Flow Rate50 L/min
Max Head45 m
Inlet Size1 inch
Outlet Size1 inch
Weight12 kg
ApplicationHousehold water supply, irrigation