EasyManua.ls Logo

onga JSP110 - User Manual

onga JSP110
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor for the correct advice before proceeding with the
installation or operation of this product.
Jet Assisted Pumps
1000 Series
JMM100 JS100 JSM100 JSK110
JS110 JSP110 JSK120
JS120 JSP120
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by a
Residual Current Device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.

Questions and Answers

  • P
    Paula MunozAug 8, 2025
    What to do if my Onga Water Pump does not start?
    • J
      Joseph WardAug 8, 2025
      If your Onga Water Pump isn't starting, ensure it's connected to a live outlet. Also, check the circuit breakers and fuses. If the pressure controller detects no water in the tank, make sure there's enough water and press the reset or start button. A blocked pump can also be the cause; disconnect it from the power and inspect the housing and discharge for any obstructions. If none of these steps work, the capacitor may be defective, and you should call a qualified service technician.
  • K
    Kevin MitchellAug 13, 2025
    Why does my onga JSP110 have poor performance with low pressure?
    • S
      Sharon RoyAug 14, 2025
      To troubleshoot low pressure or flow in your Onga Water Pump, first, check the suction line for leaks, especially at the joints. If the tank water level is too far below the pump, consider discussing a better pump option with your Onga dealer or moving the pump closer to the tank. Also, a worn or damaged pump can cause poor performance, so ask your Onga dealer to investigate worn parts.
  • R
    Rebecca GrahamAug 19, 2025
    What to do if there is no water from onga JSP110?
    • Z
      Zachary StrongAug 19, 2025
      If your Onga Water Pump isn't providing water, first ensure the pump body and suction line are filled with water before starting. Check the suction line for leaks, particularly at the joints. Blockages in the pump or discharge can also prevent water flow, so disconnect the pump from power and inspect for foreign matter. Make sure all valves on the tank, pump, and outlets are open. If the tank doesn't have enough water, wait until it refills and then press the reset or start button on the pressure controller. Also, check and clean the pump if it's not producing enough pressure, and inspect/clean any in-line or tap filters that may be blocked. Finally, check system pressure and adjust the pressure switch accordingly.
  • E
    Emily TaylorAug 26, 2025
    Why does my onga JSP110 Water Pump run intermittently?
    • H
      Harry HuntAug 26, 2025
      If your Onga Water Pump runs intermittently, start by checking for small leaks in your household plumbing and fix them. Ensure that the water temperature remains within the specified limits. Verify that the voltage is within the allowable limits as stated in the specifications, and correct if necessary. Also, make sure there's adequate ventilation for the motor cooling fan.
  • S
    sarah06Aug 31, 2025
    What to do if onga JSP110 will not stop?
    • M
      matthew27Aug 31, 2025
      If your Onga Water Pump won't stop, even with no taps open, debris might be caught in the pressure controller; take it to your Onga dealer for service. Also, check for leaks in the household plumbing and fix them.

Summary

Model Data

Application

Installation

Preparation for Installation

Inspect pump for damage, ensure suction piping is free of air leaks.

Pump Protection

Protect pump from weather, dust, vermin, and chemicals using a weatherproof enclosure.

Pipe Installation

Connect pipes carefully, support them, use flexible unions, and teflon tape for sealing.

Locating the Pump

Position pump close to water source on a stable footing.

Power Source

Arrange for an electrician to install a suitable outdoor 10A electrical outlet near the pump.

Suction

Proper suction setup is critical for performance and longevity; install a gate valve at tank outlets.

Discharge

Pipework length and diameter affect pressure/flow. All components must exceed pump pressure rating.

Pump Priming

Ensure pump and suction line are full of water before operation; check for leaks.

Electrical Installation

Operation

Start-up; Operation

Prime the pump, ensure it's full of water before starting.

Pressure Switch

Details on how to install and adjust the pressure switch for JSK models.

Aqua Packs

Aqua Packs need pre-charging with air; installation and maintenance are important.

Aqua Pack Tank Recharge Procedure

Periodic checking and recharging of air pressure in Aqua Packs is necessary.

Service and Maintenance

General Care and Maintenance

No lubrication needed; empty and rinse pump if stored long-term. Check pressure/power absorption.

Troubleshooting

Pentair Water Product Warranty

onga JSP110 Specifications

General IconGeneral
ModelJSP110
Frequency50Hz
Inlet Size1 inch
Outlet Size1 inch
Voltage220-240V