OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor for the correct advice before proceeding with the
installation or operation of this product.
Jet Assisted Pumps
1000 Series
JMM100 JS100 JSM100 JSK110
JS110 JSP110 JSK120
JS120 JSP120
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by a
Residual Current Device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.

Questions and Answers

  • C
    christy26Aug 7, 2025
    What to do if my Onga Water Pump does not start?
    • J
      John BartonAug 8, 2025
      If your Onga Water Pump isn't starting, ensure it's connected to a live outlet. Also, check the circuit breakers and fuses. If the pressure controller detects no water in the tank, make sure there's enough water and press the reset or start button. A blocked pump can also be the cause; disconnect it from the power and inspect the housing and discharge for any obstructions. If none of these steps work, the capacitor may be defective, and you should call a qualified service technician.
  • C
    Cynthia ChenAug 13, 2025
    Why does my onga JSP120 Water Pump have poor performance with low pressure?
    • G
      gregory41Aug 14, 2025
      To troubleshoot low pressure or flow in your Onga Water Pump, first, check the suction line for leaks, especially at the joints. If the tank water level is too far below the pump, consider discussing a better pump option with your Onga dealer or moving the pump closer to the tank. Also, a worn or damaged pump can cause poor performance, so ask your Onga dealer to investigate worn parts.
  • J
    Julia RussellAug 19, 2025
    What to do if there is no water from onga JSP120?
    • V
      Veronica WaltonAug 19, 2025
      If your Onga Water Pump isn't providing water, first ensure the pump body and suction line are filled with water before starting. Check the suction line for leaks, particularly at the joints. Blockages in the pump or discharge can also prevent water flow, so disconnect the pump from power and inspect for foreign matter. Make sure all valves on the tank, pump, and outlets are open. If the tank doesn't have enough water, wait until it refills and then press the reset or start button on the pressure controller. Also, check and clean the pump if it's not producing enough pressure, and inspect/clean any in-line or tap filters that may be blocked. Finally, check system pressure and adjust the pressure switch accordingly.
  • P
    Pamela GonzalezAug 26, 2025
    Why does my onga JSP120 Water Pump run intermittently?
    • S
      Stacey EstesAug 26, 2025
      If your Onga Water Pump runs intermittently, start by checking for small leaks in your household plumbing and fix them. Ensure that the water temperature remains within the specified limits. Verify that the voltage is within the allowable limits as stated in the specifications, and correct if necessary. Also, make sure there's adequate ventilation for the motor cooling fan.
  • S
    sgarciaSep 1, 2025
    What to do if onga JSP120 will not stop?
    • B
      barbaramaldonadoSep 1, 2025
      If your Onga Water Pump won't stop, even with no taps open, debris might be caught in the pressure controller; take it to your Onga dealer for service. Also, check for leaks in the household plumbing and fix them.

Summary

Jet Assisted Pumps

Model Data

Application

Installation

Preparation for Installation

Inspect pump for shipping damage and ensure suction piping is free of air leaks.

Pump Protection

Protect pump from weather, floods, chemicals, dust, vermin, and insects in a weatherproof enclosure.

Pipe Installation

Support pipes to prevent strain on pump casing; use flexible pipe or unions.

Locating the Pump

Position pump as close to the water source as possible on a separate footing.

Power Source

Arrange for an electrician to install an outdoor 10A GPO electrical outlet near the pump.

Suction

Ensure suction pipe is correctly installed for system performance and longevity; install gate valve.

Discharge

Consider length and diameter of discharge hoses/pipes affecting pressure and flow rate.

Pump Priming

Ensure pump and suction line are full of water before operation; check for leaks.

Electical Installation

Connect pump to suitable socket outlet, ensuring splash-proof protection; use RCD for safety.

Operation

Start-up; Operation

Priming procedure and operation for JMM, JSM & JSP models, including pressure controller restart.

Pressure Switch

Details on pressure switch installation and adjustment for JSK models.

Aqua Packs

Information on charging and installing Aqua Packs before use.

Aqua Pack Tank Recharge Procedure

Procedure for checking and recharging Aqua Pack air pressure.

Service and Maintenance

General Care and Maintenance

No lubrication needed; empty and rinse pump if stored for long periods; check pressure and power absorption.

Troubleshooting

Pump does not Start

Check electricity, circuit breakers, fuses, water level, and pump blockages.

Pump will not stop

Check pressure controller, leaks in plumbing, and ensure pump is primed.

No Water From Pump

Verify pump priming, check suction line for leaks, ensure valves are open, and check water level.

Pump does not produce enough pressure

Check pump, pressure switch adjustment, and clean filters.

Pump Runs Intermittently

Address small leaks, water temperature, voltage limits, and motor cooling.

Poor Performance - low pressure or flow

Check suction line leaks, tank water level, and pump wear.

Pentair Water Product Warranty

Terms and Conditions Applicable Internationally

Warranty duration for parts internationally is 12 months from date of purchase.

Terms and Conditions Applicable in Australia and New Zealand

Warranty for parts is 24 months; labour is 12 months; commercial application is 6 months.

What the warranty covers

Covers defects in material and workmanship; repair or replacement at Pentair's option.

What the warranty does not cover

Excludes damage from accident, misuse, unauthorized repair, shipment, installation, wear, or external causes.

How to get service

Contact numbers for Australia/NZ; provide product details, proof of purchase, and contact information.

Limitation of implied warranties

No warranties implied beyond description, including merchantability and fitness for purpose.

Exclusion of damages

Pentair's liability limited to repair/replacement cost; excludes consequential damages.

onga JSP120 Specifications

General IconGeneral
Brandonga
ModelJSP120
CategoryWater Pump
LanguageEnglish

Related product manuals