OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor/manufacturer for the correct advice before proceeding
with the installation or operation of this product.
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by
a residual current device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.
Horizontal Multistage
Centrifugal Pumps
SMH Range
SMH35 SMH45 SMH55 SMH75 SMH90

Questions and Answers

  • M
    meganbaxterAug 1, 2025
    What to do if my onga SMH35 operates but delivers no water?
    • G
      Gail MayAug 1, 2025
      If your Onga Water Pump runs but doesn't deliver water, several issues could be the cause. First, ensure the pump is filled with water. Next, the suction head might be too high, or the foot valve/strainer isn't submerged enough; try lengthening the suction pipe, but no more than 8 meters. Check for air leaks in the suction pipe and joints. Also, the suction pipe/strainer or non-return valves might be clogged with debris, or the pump itself might be clogged. Cleaning these components may resolve the issue.
  • J
    Jennifer GilbertAug 9, 2025
    Why my onga SMH35 does not operate and the motor does not run?
    • D
      Dr. Eric ManningAug 9, 2025
      If your Onga Water Pump isn't operating and the motor isn't running, there are a few potential causes. First, verify that there is electricity available to the pump. Next, make sure the pump is plugged in correctly. Finally, check if the circuit breaker has been activated, and if so, reset it.
  • K
    Kenneth HopkinsAug 16, 2025
    How to troubleshoot reduced performance in Onga Water Pump?
    • K
      katie94Aug 16, 2025
      To troubleshoot reduced performance in your Onga Water Pump, consider these potential causes: the suction head might be too high, so reduce it. If the foot valve/strainer is only partially submerged, try lengthening the suction pipe. A worn or damaged pump shaft seal can cause this issue, so replace any defective parts. Debris partially blocking the pump can also reduce performance; remove any debris and flush the pump with clean water. Lastly, check the pressure switch settings and adjust them if they are incorrectly set, or replace faulty parts.
  • L
    lindsaycarpenterAug 25, 2025
    What to do if onga SMH35 Water Pump hums and the thermal relays cut in and out?
    • D
      douglas96Aug 25, 2025
      If your Onga Water Pump is humming and the thermal relays are cutting in and out, it could be due to a few reasons. The pump might be clogged by debris, in which case you should clean the suction pipe and foot valve/strainer. Flush the pump with water and remove the priming and drain plugs. If it still doesn't start, dismantle and clean it. Alternatively, the capacitor might be defective and need replacement.

Summary

Model Data

Technical Information

Product specifications including inlet/outlet size, temperature limits, IP rating, and electrical supply.

Installation

Suction

Critical installation aspect for performance and longevity, detailing pipe size and submersion requirements.

Pump Priming

Step-by-step instructions for filling the pump body and suction line with water before operation.

Electrical

Instructions for connecting the pump to the power supply, including splash-proof connections and socket location.

Operation

Start-up; Operation

Procedures for ensuring the pump is primed and checking motor rotation direction before starting.

Service and Maintenance

Troubleshooting

onga SMH35 Specifications

General IconGeneral
Brandonga
ModelSMH35
CategoryWater Pump
LanguageEnglish

Related product manuals