OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor/manufacturer for the correct advice before proceeding
with the installation or operation of this product.
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by
a residual current device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.
Horizontal Multistage
Centrifugal Pumps
SMH Range
SMH35 SMH45 SMH55 SMH75 SMH90

Questions and Answers

  • E
    Elizabeth LozanoAug 8, 2025
    What to do if my onga SMH45 Water Pump operates but delivers no water?
    • J
      Jacob WilsonAug 8, 2025
      If your Onga Water Pump runs but doesn't deliver water, several issues could be the cause. First, ensure the pump is filled with water. Next, the suction head might be too high, or the foot valve/strainer isn't submerged enough; try lengthening the suction pipe, but no more than 8 meters. Check for air leaks in the suction pipe and joints. Also, the suction pipe/strainer or non-return valves might be clogged with debris, or the pump itself might be clogged. Cleaning these components may resolve the issue.
  • C
    Carol ShahAug 16, 2025
    Why my onga SMH45 Water Pump does not operate and the motor does not run?
    • K
      Katie WelchAug 16, 2025
      If your Onga Water Pump isn't operating and the motor isn't running, there are a few potential causes. First, verify that there is electricity available to the pump. Next, make sure the pump is plugged in correctly. Finally, check if the circuit breaker has been activated, and if so, reset it.
  • L
    Lisa KramerAug 23, 2025
    How to troubleshoot reduced performance in Onga Water Pump?
    • S
      Shaun JensenAug 23, 2025
      To troubleshoot reduced performance in your Onga Water Pump, consider these potential causes: the suction head might be too high, so reduce it. If the foot valve/strainer is only partially submerged, try lengthening the suction pipe. A worn or damaged pump shaft seal can cause this issue, so replace any defective parts. Debris partially blocking the pump can also reduce performance; remove any debris and flush the pump with clean water. Lastly, check the pressure switch settings and adjust them if they are incorrectly set, or replace faulty parts.
  • F
    fshermanAug 30, 2025
    What to do if onga SMH45 Water Pump hums and the thermal relays cut in and out?
    • S
      sellerslarryAug 30, 2025
      If your Onga Water Pump is humming and the thermal relays are cutting in and out, it could be due to a few reasons. The pump might be clogged by debris, in which case you should clean the suction pipe and foot valve/strainer. Flush the pump with water and remove the priming and drain plugs. If it still doesn't start, dismantle and clean it. Alternatively, the capacitor might be defective and need replacement.

Summary

Model Data

Technical Information

Details specifications like inlet/outlet size, temperature range, IP rating, and electrical supply.

Application

Installation

Preparation for Installation

Inspect pump for shipping damage and ensure suction piping is free of air leaks.

Pump Protection

Protect the pump from weather, chemicals, dust, and vermin using a weatherproof enclosure.

Pipe Installation

Connect pipes carefully, support them to avoid strain, and use teflon tape for sealing.

Locating the Pump

Position the pump close to the water source on a separate footing.

Power Source

Arrange for an electrician to install an outdoor 10A GPO electrical outlet near the pump.

Suction

Ensure suction pipe is kept short, crush-resistant, air-tight, and submerged.

Discharge

Discharge hose/pipe diameter and length affect pressure/flow. Ensure pressure ratings exceed pump max.

Pump Priming

Ensure pump has water before operating; fill pump body and suction line if needed.

Electrical

Connect pump using provided connectors to a suitable socket outlet, avoid extension cords.

Operation

Start-up; Operation

Ensure pump is primed, check motor rotation direction (clockwise).

D.R.O.P (Dry Running Over-Temperature Protection)

Protects pump parts from overheating due to running dry; reset using condenser box switch.

Restoring Operation

Steps to restore operation after a malfunction, involving switching off and cooling down.

Service and Maintenance

General Care and Maintenance

Requires minimal attention; periodically check pressure and power absorption for wear.

Troubleshooting

Pentair Water Product Warranty

onga SMH45 Specifications

General IconGeneral
Brandonga
ModelSMH45
CategoryWater Pump
LanguageEnglish