OWNER’S MANUAL
Should you the installer or owner be unfamiliar with the correct
installation or operation of this type of equipment you should contact
the distributor/manufacturer for the correct advice before proceeding
with the installation or operation of this product.
We recommend, for additional protection, the pump
to be supplied from socket outlet protected by
a residual current device – RCD (also known as
an Earth Leakage Circuit Breaker – ELCB) with a
maximum rated residual current of 30mA.
Horizontal Multistage
Centrifugal Pumps
SMH Range
SMH35 SMH45 SMH55 SMH75 SMH90

Questions and Answers:

onga SMH45 Specifications

General IconGeneral
Brandonga
ModelSMH45
CategoryWater Pump
LanguageEnglish

Summary

Model Data

Technical Information

Details specifications like inlet/outlet size, temperature range, IP rating, and electrical supply.

Application

Installation

Preparation for Installation

Inspect pump for shipping damage and ensure suction piping is free of air leaks.

Pump Protection

Protect the pump from weather, chemicals, dust, and vermin using a weatherproof enclosure.

Pipe Installation

Connect pipes carefully, support them to avoid strain, and use teflon tape for sealing.

Locating the Pump

Position the pump close to the water source on a separate footing.

Power Source

Arrange for an electrician to install an outdoor 10A GPO electrical outlet near the pump.

Suction

Ensure suction pipe is kept short, crush-resistant, air-tight, and submerged.

Discharge

Discharge hose/pipe diameter and length affect pressure/flow. Ensure pressure ratings exceed pump max.

Pump Priming

Ensure pump has water before operating; fill pump body and suction line if needed.

Electrical

Connect pump using provided connectors to a suitable socket outlet, avoid extension cords.

Operation

Start-up / Operation

Ensure pump is primed, check motor rotation direction (clockwise).

D.R.O.P (Dry Running Over-Temperature Protection)

Protects pump parts from overheating due to running dry; reset using condenser box switch.

Restoring Operation

Steps to restore operation after a malfunction, involving switching off and cooling down.

Service and Maintenance

General Care and Maintenance

Requires minimal attention; periodically check pressure and power absorption for wear.

Troubleshooting