OPERATION CHECK-2
OUTPUT LEVEL & THERMAL DETECTION
TX-SR502/E/8250/HT-R520
RL6901
D6904
D6903
RL6902
POWER AMP.
PRI.
SEC1
Low
High
+B1
-B1
T901 MAIN
TRANSFORMER
Low
High
Q6303
THERMAL
SENSOR
R6380
THERMAL
DETECTION
OUTPUT
LEVEL
DETECTION
VOLH
Q7008
MAIN
MICROPROCESSOR
Q6901
SEC1H
23
2
SPEAKER
OUT
F6901
F6902
Low-voltage
<Block diagram>
TX-SR502
502E//8250
HT-R520
HIGH
MODE
LOW
MODE
+/- 53.0 V
+/- 35.0 V
+/- 68.0 V
+/- 33.5 V
High-voltage
Regarding the power supply system of this unit.
<Function>
1. High-voltage mode
Usually, the power supply supplies high voltage to the power amplifier circuit when the relay(RL6901) is turned on.
2. Low-voltage mode
When as follows, a power supply changes to the state of supplying low voltage when the relay (RL6901) in turned off.
(1) Excessive output signal is continuously outputted from power amplifier.
(2) Temperature of a heat sink over 80 degrees.
<Purpose>
1. The loss which power amplifier generates is decreased. As a result, the miniaturization of a heat sink is realized.
2. Corresponds to a safety standard.
<Necessity for a check of operation>
May not notice the fuse (F6901, F6902) broken in the case of repair.
Because the power supply is continuing supplying voltage from the High side of SEC1 at high-voltage mode.
When a power supply Circuit changes to low voltage mode, amplifier does not operate.
Therefore, it is very important to check operation of this power supply system containing a fuse.
<Procedure>
[NOTE2]
Don't connect speakers or any load.
Don't short speaker terminals.
(1) Set the unit is Multi channel input state.
(2) Set the master volume into the minimum.
(3) Apply sine wave signal to MULTI CHANNEL INPUT (FL+FR+C+SL) terminals.
(4) Connect an oscilloscope to speaker terminal of FL channel.
(5) Adjust master volume so that a speaker output may become distortion about 5%.
(6) Check that the RL6901 is turned off after about 5 seconds.
And the power supply changes to low-voltage mode.
(7) Adjust the master volume so that output voltage may become half.
(8) Check that the RL6901 is turned ON after 2 to 3 minutes.
And the power supply returns to high-voltage mode.

Table of Contents

Other manuals for Onkyo HT-R520

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onkyo HT-R520 and is the answer not in the manual?

Onkyo HT-R520 Specifications

General IconGeneral
BrandOnkyo
ModelHT-R520
CategoryReceiver
LanguageEnglish

Related product manuals